User Manual

-
11
-
T
he value on the left side of second line sets a charge
current and the value on the right side of second lines
sets the voltage of the battery pack.
After setting the current and voltage press Start/ Enter
key for more than 3 seconds to start the process.
(Charge current:0.1~6.0A, Volatge:3.7~22.2V)
This shows the number of cells you set up and the
processor detects.' R: ' shows the number of cells found
by the charger and ' S:' is the number of cells selected by
you at the previous screen. If both numbers are identical
you can start charging by press Start /Enter button. If
not, press Batt type/Stop button to go back to previous
screen. Then carefully check the number of cells of the
battery pack to charge again.
The screen shows the present situation during charge
process. To stop charging press Batt type/Stop key once.
BALANCE
6.3 'FAST' charging of Lithium battery
The charging current is getting smaller as the process goes to the near end term of
Lithium battery chaging. To nish charging process earlier, this program eliminate certain term
of CV process. Actually, the charging current will goes to 1/5 from the initial value to end the
process while the normal chaging goes to 1/10 during CV term. The charging capacity may
be a bit smaller than normal charging but the process time will be reduced.
The value on the left side of the second lines sets the
charge current. The value on the right side of the second
lines sets the battery pack’s voltage. After setting current
and voltage, press Start/Enter for more than 3 second to
start the process.
This shows the number of cells you set up and the
processor detects.' R: ' shows the number of cells found
by the charger and ' S:' is the number of cells selected by
you at the previous screen. If both numbers are identical
you can start charging by press Start /Enter button. If
not, press Batt type/Stop button to go back to previous
screen. Then carefully check the number of cells of the
battery pack to charge again.
The shows the present state of 'FAST' charging. To stop
charging arbitrary, press Batt type/Stop key once
.