User Manual
-
16
-
It has a data storage and load program for your convenience. This feature can store up to
5 battery data by number that represent the individual specication of batteries you are using.
They can be called back for the process of charging or discharging without setting up the
program again. To set up the parameter value in the program, press Start/Enter key to make
it blink then change the value with INC or DEC key.
9. Save Data Program
Program select.
The parameter valaue setting up in this screen does not
affect charge or discharge process. They only represent
the specification of the battery. The following screens
will automatically be displayed exactly matched battery
type you set up. The example shows the battery pack of
NiMH, 12cells and 3000mAh of capacity.
Set up the charge current for manual charge mode, or the
current limit for automatic charge mode. Each mode can
be switched by pressing INC and DEC button at the same
time when the current eld is blinking.
Set up discharge current and nal voltage.
Set up the charge/discharge sequence and the cycle
number.
Saving the data.