User Manual

-
14
-
7.2 Discharging of NiCd/NiMH battery
Set discharge current on the left and nal voltage on the
right. The discharge current ranges from 0.1 to 1.0A and
the nal voltage ranges from 0.1 to 25.0V). To start the
process, press Start /Enter key more than 3 seconds.
The screen displays the current state of discharge. You
can alter the discharge current by pressing Start/Enter
key during the process. Once you change the current
value, store it by pressing Start/Enter button again.
To stop discharging press Batt type/Stop key once. The
audible sound indicated you at the end of process.
7.3 Charge/discharge & discharge/charge cycle of NiMH/NiCd battery
Set the sequence on the left and the number of cycle
on the right. You can use this function for balancing,
refreshing and break-in the battery. To avoid rising
temperture of the battery, there will a brief cool-off
period that already fixed at 'User setting' after each
charge and discharge process. The cycling number
ranges from 1 to 5.
To stop the process, press Batt type/Stop key once.
You can change the discharge or charge current by
pressing Start/Enter key once during the process. The
audible sound indicates you the end of process.
At the end of the process, you can see charged or
discharged electric capacities of the battery at each cyclic
process.
By pressing INC or DEC button, the screen shows the
result of each cycle in order.