User Manual

-
10
-
The beep sounds at every time pressing the buttons to
confirm your action. The beep or melody sounded at
various times during operation to alert different mode
changes. These audible sounds can be on or off.
This program monitors the voltage of input battery. If
the voltage drops below the value you set the operation
forcibly terminated to protect the input battery.
6. Lithium battery(Lilo/LiPo/LiFe)program
These programs are only suitable for charging and discharging Lithium batteries with
a nominal voltage of 3.3V, 3.6V and 3.7V per cell. These batteries need to adopt different
charge technique is termed a constant voltage(CV) and constant current(CC) method. The
charge current varies according to the battery capacity and performance. The nal voltage
of charge process is also very important; it should be precisely matched with the charade
voltage of the battery. They are 4.2V for LiPo, 4.1V for Lilo, and 3.6 V for LiFe. The charge
current and nominal voltage as for cell count set on the charge program must always be
correct for the battery to be charged.
When you are willing to alter the parameter value in the program, press Start/Enter key to
make it blink then change the value with INC or DEC key. The value will be stored by pressing
Start/Enter key once.
6.1 Charging of Lithium Battery
This charging mode is for LiPo/LiIo/LiFe battery without balance lead.
The left side of the first line shows the type of battery you
select at the users setting. The value on the left side of
second line sets a charge current and the value on the right
side of second line sets the voltage of the battery pack.
After setting the current and voltage press Start/Enter
key for more than 3 seconds to start the process.
(Charge current:0.1~6.0A,Voltage:3.7~22.2V)
This shows the number of cells you set up and the
processor detects. ' R:' shows the number of cells found
by the charger and ' S:' is the number of cells selected by
you at the previous screen. If both numbers are identical
you can start charging by press Start/Enter button. If
not, press Batt Type/Stop button to go back to previous
screen. Then carefully check the number of cells of the
battery pack to charge again.
The screen shows the present situation during charge
process. To stop charging press Batt Type/Stop key once
.