User Manual
-13-
6.5 Discharging Lithium battery
Number
of
cells
DEC
-
Batt type
Stop
elapsed
time
INC
+
Battery
voltage
DEC
Start
Enter
-
INC
+
Discharged
capacity
The value of discharge current on the left can not exceed 1C, and
the value on the right can not be under the voltage recommended
by the manufacturer to avoid deep discharging. Press Start/Enter
for more than 3 seconds to start discharging.
discharge
current
This shows the real-time status of discharging, you can press Batt
Type/Stop key to stop discharging.
'> 3 seconds '
Start
Enter
This displays the number of cells you set up and the processor
detects. R shows the number of cells detected by the charger and
S is the number of cells set by you at the previous screen. If both
numbers are identical you can start charging by press Start/Enter
button. If not, press Batt Type/Stop button to go back to previous
screen to carefully check the number of cells of the battery pack
before going ahead.
6. Lithium battery(LiPo/Lilo/LiFe)program