14Cycle Life
Discharge to 1.3V at 300mA;
Charge 120 minutes at 750mA constant
current with a voltage holding at 1.9V;
Constant voltage holding at 1.9V to
charge 90 minutes until current drops to
50mA;
Rest for 15 minutes;
Discharge to 1.2V at a constant current
at 1500mA;
Repeat steps from to until the
capacity drops to 60%.
The cycles life shall exceed
200
times
15Leak-proof
test
Standard charge and store for 14 days
under the following storage
conditions 33±3 Relative
humidity: 80%±5%.
No leakage of electrolyte in
liquid form shall be
observed
16Vibration
test
Store the cell more than 24 hours
after standard charge, following
vibration tests over an amplitude of 4
mm (0.1575 inches) at a frequency of
16.7 Hz(1000 cycles per minute) and
repeated through any axes during
60mins
The subsequent fluctuation of
open circuit voltage and
internal impedance shall be
less than 0.02
V and 5 m
respectively, and the surface
of cell has no obvious change.
17Free falling:
(Drop)
Store the cell more than 24 hours
after standard charge, following a
drop test from 450mm (17.717
inches ) on to a hard-wood board in a
vertical axis 3 times .
The subsequent fluctuation of
open circuit voltage and
internal impedance shall be
less than 0.02
V and 5 m
respectively, and the surface
of cell has no obvious change.
18Safety
testing
to store it for 1 hour after standard
charged, and to make positive and
negative electrode short-circuit with a
wire with the section 0.75mm
2
min
and shortest length, the short-circuit
time is 1 hour
It shall not explode . However,
leakage of electrolyte, external
deformation or outer sleeve
cracking is permitted.
19. Safety Valve
Start
Performance
(Over dis-
charging)
to be charged with 1500
mA for 5
hours
safety valve can work
normally, no breakage,
leakage, distortion and out
package breakage are allowed
20. Safty Valve
Start
Performance
to be charged with 1500
mA for 5
hours
No explosion, but leakage,
distortion and out package