User Manual
Conrad Electronic SE · Klaus-Conrad-Str.1 · 92240 Hirschau
H
D
D1
H1
(6)The outer case of battery , after tin-plated processing, the place is a little soft . For example, in
the battery use process, it is normal that the battery shell base presents the scratch. The
determination standard should be taken the bilateral consultation as a standard.
3.Measurement & Dimensions
to see the drawing:
D 14.5-0.7 mm
H 51.0-1.0 mm
4. TEST
4.1 Test conditions:
4.1.1 The battery to be tested is the product within one month after being received by customer.
4.1.2 Ambient conditions:
Temperature +20±5
Humidity +65%±20%
4.2 Testing Tools
4.2.1 Voltage meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10KΩ/V.
4.2.2 Current meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than
0.01Ω/V(including wires).
4.2.3. Micrometer caliper:
With precision of 0.02mm.
4.2.4. Internal impedance meter:
Alternating current of 1000HZ, connector measuring equipment with sin wave of 4.
4.2.5: Impedance loaded meter:
Value of impedance is with +
5% error allowed (including external wires).
4.3 Test methods and benchmarks
Items Test Methods Benchmarks
1.Appearance:
eyeballing
batteries shall be free from
any stains; scratches or
deformations, which may
reduce the commercial value
when visually inspected
2.Size: caliper measurement。
The size shall comply with the
specified size as the attached
drawing
3.Insulate
impedance
measured with a Megger overpack
and battery electrode between the
degree of insulation。
outer sleeve shall exceed 10
MΩ。