User Manual
User Manual of “TURNIGY” Series Brushless Speed Controller Doc Ver. HK-13-V2-101119 Page - 4 -
3.8. Throttle Neutral Range: Please see the following illustrations to adjust the neutral range as your like.
3.9. Timing: There are many differences among structures and parameters of different brushless motors, so a
fixed timing ESC is difficult to be compatible with all brushless motors. It is necessary to make the
timing value programmable. Please select the most suitable timing value according to the motor you are using.
Generally, higher timing value brings out higher power output, but the whole efficiency of the system will be
slightly lower down.
3.10. Over-Heat Protection: If the function is activated, the output power will cut-off when the temperature of
the ESC is up to a factory preset threshold for more than 5 seconds. When the protection cuts in the Green LED
will flash.
4. Reset All Items To Default Values
At any time when the throttle is located in neutral zone (except in the throttle calibration or parameters program
process), hold the “SET” key for over 3 seconds, the red LED and green LED will flash at the same time , which
means each programmable item has be reset to its default value.
USER MEMO