User Manual

voltage should be matched with the battery
being charged.
Start the charge process by pressing
Start/Enter key for more than 3 seconds.
The screen displays the state of charging
process. To stop charging forcibly, press Batt
type/Stop key once.
The audible sound indicates you at the end of
process.
Discharging Pb battery
Set discharge current on the left and final
voltage on the right. The discharge current
ranges from 0.1 to 1.0A.
To start the process, press Start/Enter key for
more than 3 seconds.
The screen displays the current state of
discharge. You can alter the discharge current
by pressing Start/Enter key during the
process. Once you change the current value,
store it by pressing StartEnter button again.
To stop discharging press Batt Type/ Stop key
once. The audible sound indicates you at the
end of process.
Save Data Program
It has a data storage and load program for your convenience. This feature
can store up to 5 battery data by number that represent the individual specifi-
cation of batteries you are using. They can be called back for the process of
charging or discharging without setting up the program again. To set up the
parameter value in the program, press Start/Enter key to make it blink then
change the value with INC or DEC key.
The parameter valaue setting up in this screen
does not affect charge or discharge process.
They only represent the specification of the
battery. The following screens will automati-
cally be displayed exactly matched with the