User Manual
-
14
-
8.3 Charge-to-discharge & discharge-to-charge cycle NiMH/NiCd battery
8.4 NiMH RE-PEAK
Set the sequence on the left and the number of cycle
on the right. You can use this function for balancing,
refreshing and break-in the battery. To avoid rising
temperture of the battery, there will a brief cool-off
period that already fixed at 'User setting' after each
charge and discharge process. The cycling number
ranges from 1 to 5.
To stop the process, press Batt type/Stop key once.
You can change the discharge or charge current by
pressing Start/Enter key once during the process. The
audible sound indicates you the end of process.
At the end of the process, you can see charged or
discharged electric capacities of the battery at each
cyclic process.
By pressing INC or DEC button, the screen shows the
result of each cycle in order.
NiMH RE-PEAK
1
NiMH 2.0A 7.42V
RPC 022:45 00890
The charger has the new program which can charge
the battery for second time. (The battery which do not
using for a long time or the old battery or the battery
which can not arrive the Max voltage after the first
charge). In this way, this mode can make the battery’s
capacity to the standard value and make the battery’s
life for longer time.
Long press Enter key into charging program, the
charging current is the defaulted previous NIMH
battery charging current, and press STOP key back.
(1-3)