This shows the trigger voltage for automatic
charge termination of NiMH and NiCd battery.
The effective value ranges from 5 to 20mV per
cell .if the trigger voltage is set higher, there is
a danger of overcharging the battery; if it is set
lower, there is a possibility of premature
termination. Please refer the technical specifi-
cation of the battery.(NiCd default:12mV, NiMH
default:7mV)
You can select the function of 3-pin port at left
side of the unit.It can be used temperature
sensor port or USB port, selected at this
screen. If the port is assigned as a temp. port,
an optional temperature probe contacting the
surface of battery can be used. When it is
selected as an USB port, you can link the
charger to your PC via an optional USB cable.
This can utilize the optional software that can
show you the charge process at PC.
You can set the maximum temperature at
which the charger should allow battery to
reach during charge. Once a battery reaches
this temperature during charge, the process
will be terminated to protect the battery.
The battery is on the cyclic process of charge
and discharge can often become warm after
charge or discharge period. The program can
insert a time delay to occur after each charge
and discharge process to allow the battery
adequate time to cool down before being
subjected to the next process. The value
ranges from 1 to 60 minutes.
When you start a charge process, the integral
safety timer automatically starts running at the
same time. This is programmed to prevent
overcharge the battery if it proves to be faulty,
or if the termination circuit cannot detect the
battery full. The value for the safety timer
should be generous enough to allow a full
charge of the battery .