User Manual

Warnings and safety notes
�Never leave the charge unsupervised when it is connected to its power
supply. If any malfunction is observed immediately terminate the process and
refer to the operation manual.
�Keep away the unit from dust, damp, rain, heat direct sunshine and
vibration. Do not dorp it.
�The circuit of the unit is designed to be powered by a 10-18V DC only.
�This unit and the battery to charge or discharge should be set up on a
head-resistant, non-inflammable and non-conductive surface. Never place
them on a car seat, carpet or similar. Keep all the inflammable volatile materi-
als well away from operating area.
�Be sure to understand the information of the battery to be charged or
discharged accurately. If the program is set up incorrectly the battery can
severely be damaged. Especially Lithium battery can cause a fire or an
explosion by over-charging.
NiCd/NiMH voltage level:1.2V/cell
allowable fast charge current:1C~2C depends on the
performance of cell discharge voltage cut off level
0.85V/cell(NiCd), 1.0V/cell(NiMH)
Lilo voltage level:3.6V/cell
max.charge voltage:4.1V/cell
allowable fast charge current: 1C or less
min.discharge voltage cut off level:2.5V/cell or higher
LiPo voltage level:3.7V/cell
max.charge voltage:4.2V/cell
allowable fast charge current: 1C or less
discharge voltage cut off level:3.0V/cell or higher
Life voltage level:3.3V/cell
max.charge voltage:3.6V/cell
allowable fast charge current: 4C or less(e.g. A123M1)
discharge voltage cut off level:2.0V/cell or higher
Pb voltage level:2.0V/cell
(Lead-acid) max.charge voltage:2.46V/cell
allowable fast charge current:0.4C or less
discharge voltage cut off level:1.50V/cell or higher
�To avoid short-circuits between the charge lead, always connect the charge
cable to the unit first and only then to the battery to be charged or discharged.
Reverse the hsequence when disconnecting.