User Manual
To stop discharging press Batt type/ Stop key
once. The audible sound indicated you at the
end of process.
Charge-to-discharge & discharge-to-charge cycle NiMH/NiCd battery
Set the sequence on the left and the number of
cycle on the right. You can use this function for
balancing, refreshing and break-in the battery.
To avoid rising temperture of the battery, there
will a brief cool-off period that already fixed at
‘User setting’ after each charge and discharge
process. The cycling number ranges from 1 to
5.
To stop the process, press Batt type/Stop key
once.
You can change the discharge or charge
current by pressing Start/Enter key once
during the process. The audible sound
indicates you the end of process.
At the end of the process, you can see
charged or discharged electric capacities of
the battery at each cyclic process.
By pressing INC or DEC button, the screen
shows the result of each cycle in order.
Pb( lead-sulphuric acid) battery program
This is programmed for charging Pb( lead-sulphuric acid) battery with
nominal voltage from 2 to 20V. Pb batteries are totally different from NiCd or
NiMH batteries. They can only deliver relatievely lower current compare to
their capacity, and similar restrictions definitely apply to charge. So the
optimal charge current will be 1/10 of the capacity. Pb batteries must not be
charged rapidly. Always follow the instruction is supplied by the manufacturer
of battery.
When you are willing to alter the parameter value in the program, press
Start/Enter key to make it blink then change the value with INC or DEC key.
The value will be stored by pressing Start/Enter key once.
Charging Pb battery
Set up the charge current on the left and the
nominal voltage of the battery on the right. The
charge current ranges from 0.1 to 5.0A and the