www.turbro.com Tips for First-Time Use 1. Allow the unit to sit upright for at least 3-4 hours before powering on. Shipping carriers may set the unit on its side, which causes the refrigerant to pool in certain areas. Standing the unit upright for 3-4 hours allows the refrigerant to move freely within the coils. 2. Some parts with sharp edges may cause injury, so gloves are highly recommended for unpacking and installing. 3.
wwwi.turbro.com CONTENTS SAFETY INFORMATION: senselessness 01 PARTS DESCRIPTION: rest eases assess assess 03 INSTALLATION INSTRUCTIONS assassins 04 Installation Location-Tool Suggested -. Installing In Double-Hung Sash / Sliding Casement Windows Installing Exhaust Hose OPERATING INSTRUCTIONS.-Control Panel Operating from the Control Panel Operating from the Remote Control Operating from the APP Self-Diagnoses Water Drainage Methods. .
www turboprop SAFETY INFORMATION Please read all instructions before use and save this user manual for future reference. A digital version can be obtained from Customer Support. Your safety and the safety of others are very important to us. We have provided many important safety messages throughout this manual and on the appliance itself Always read and follow all posted safety messages.
wwwi.turbro.com @® This product should be plugged directly into a power outlet. Power outlets should be properly rated, protected, and sized in order to avoid electrical overload. Do not use a multiple-outlet power strip or extension cord. Failure to do so may result in short-circuit or electrical shock.
www.turbro.com A ee If the TEST button does not cause the circuit breaker trip or the RESET button will not stay engaged, unplug alr conditioner Immediately and contact TURBO Customer Support. NOTE: Do not use this device to turn the unit on or off. « Always make sure the reset button is pushed in for correct operation » The power cord must be replaced if it fails to reset when either the test button is pushed, or it cannot be reset. « If power supply cord is damaged, it cannot be repaired.
wwwi.turbro.com Hose Inlet 0 # Exhaust Hose 1st Hose Outlet TY Window Panel + Extension Panel 1st [ame] sel vy Metal Locking Screw Adjustment Panel without Hole 1st Remote Control Battery Tet Drainage Hose 1st Foam Seal 1st Installation Location 8 ION IN SUCTION @® The air conditioner should be placed on a firm floor to minimize noise and vibration.
www.turbro.com Tool Suggested Priors lean Torrent Har Read sieve Ean a EE {pe megs Sols pel The window panel kit has been designed to fit most standard windows that open vertically or horizontally; however, it may be necessary for you to improvise/modify some aspect of the installation procedures for certain types of window. Minimum and maximum window openings: 2 59 Inches NOTE: If the width of your window is smaller than 20.
wwwi.turbro.com c. Place the assembled window panels on the window sash and adjust until it fully covers the width of your window. Sines Max. 18 inches Min. = “1 ‘Window width 0 5% inches Max. / 9 inches Min. NOTE: If the width of your window is smaller than 20.5 inches, please remove the adjusting panel from the window panel and then cut the window panel to make the width of the window panel the same width as your window. d. Use the provided metal locking screws to secure the window panel kit. f.
support@turbrocom wwwi.turbro.com Installing Exhaust Hose COOL & DEHUMIDIFY: Air exhaust hose should be connected to the portable air conditioner. FAN MODE: Air exhaust hose should be disconnected from the portable air conditioner. A. Required Parts: ® Hose Inlet @® Exhaust Hose ® Hose Outlet B. Assembly: a. Align both the arrows of the Hose Inlet connector and the Exhaust Hose, then rotate the Hose Inlet clockwise or counter-clockwise to lock into place. (see Fig. 1) b.
www.turbro.com ol Timer @ Hen ood @ Seen wir@ dB Fn Low 8 Bo auto Timer Button QD Decrease Button ® Fan Speed Button (WIFI Reset) > Mode Button ® Increase Button @ ON/OFF Button m the Co I P: Operating The Control Panel enables you to manage all the main functions of the appliance, but to fully exploit its potential, you must use the remote control TURNING THE APPLIANCE ON @® Plug into the mains socket, then the appliance is in standby. ® Press the ON/OFF Button (D then the display screen will light up.
support@turbrocom wwwiturbro.com High To reach the desired temperature as rapidly as possible. Med To maintain a comfortable temperature under a comparative acceptable noise. Low To operate under low noise. Auto To run at a suitable fan speed automatically. NOTE: After reaching the set temperature, the compressor will stop working. Then the fan will work intermittently to help circulate air. When the temperature rises, the compressor will be back on.
support@turbrocom wwwiturbro.com @ Press the Mode Button 5 until the ‘Auto’ indicator lights up. Also, the screen will display like below: @ Press the Fan Button $f to select the fan speed: High / Medium / Low / Auto TIMER FUNCTION This timer can be used to delay the unit start up or shutdown, this avoids wasting electricity by optimizing operating periods. Programming start up ® Press the ON/OFF Button (Dto turn on the unit and choose your desired mode, for example ‘cooling, 68°F and high fan speed’.
support@turbrocom wwwiturbro.com fro ME xo) To turn on/off the air conditioner To select the operation mode.
support@turbrocom www.turbro.com The following functions only can be active by using the remote: SWING FUNCTION This function is useful for selecting the up/down swing of air circulation. 7” \ ® Select the operating mode (Cool, Dry, Fan) as described above @ Press the Swing Button [E on the remote to control the deflector to swing automatically or not.
www.turbro.com Inserting or replacing the batteries @® Remove the cover on the rear of the remote control @® Insert two "AAA" 1.5V batteries in the correct position (see instructions inside the battery compartment) NOTE: @® If the remote control unit is replaced or disposed of, the batteries must be removed and discarded in accordance with current legislation as they are harmful to the environment. ® Do not mix old and new batteries.
www.turbro.com Self-Diagnosis This unit has a self diagnosis system to identify a number of malfunctions. Error messages will be displayed on the display screen. @ If this is displayed, contact TURBO service team PROBE FAILURE (sensor damaged) @® Empty the internal safety tank, following the instructions in the FULL TANK ‘WATER DRAINAGE METHODS' (safety tank full) Water Drainage Methods TURBO portable air conditioner comes with the auto-evaporation system.
www.turbro.com Method B: Continuous Draining a. Unplug the unit from power source, b. Remove the drain cap from the lower or middle drain port. During this step, some residual water may spill so place a receptacle pan (does not include) under the drain port to collect the water. c. Insert the 1/2" drain hose into the drain port.
www.turbro.com close =F d t doors and te over windows curtains Cue app Before cleaning or maintenance, turn the appliance off and wait for a few minutes, then unplug from the electrical outlet. Cleaning the Outer Case You should clean the appliance with a slightly damp cloth then dry with a dry cloth @® Never wash the appliance with water. It could be dangerous @ Never use petrol, alcohol or solvents to clean the appliance. ® Never spray insecticide liquids or similar.
www.turbro.com Pr-Season Maintenance Checklist @ Check the power cord for any cuts or exposed wiring @® Check the ground prong is still on your power plug. ® Clean the air filter. ® Check whether the hose adapters and exhaust hose are installed tightly and free of damage. Post-Season Maintenance Checklist @ Disconnect unit from the power outlet. @ Clean air filter and exterior case. @® Drain any accumulated water from the air conditioner.
support@turbrocom www.turbro.com Not cool A. The windows, doors and / or A. Make sure all the doors, windows and curtains enough curtains are not closed. are closed (Refer to Tips for Correct Use’). B. There are heat sources inside B. Remove the heat sources if possible the room (oven, hairdryer, etc) C. Connect the air exhaust hoe and make sure C. The air exhaust hose is not it can function properly (Refer to ‘Installing connected or blocked the Air Exhaust Hose"). D. The temperature is set too high. D.
support@turbrocom www.turbro.com WARRANTY & CUSTOMER SUPPORT WARRANTY TURBO provides a 1-year limited warranty for TURBO products from the date of purchase, subject to the following conditions and limitations outlined below.
Cc CAN ICES-3 FCC Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.