Quick Start Guide

20 Quick Start Guide 21TSP-AN Series
Networking capability
All TSP-AN powered loudspeakers oer remote control via USB. The USB connection allows the user to congure and monitor all DSP parameters using dedicated
control software for PC.
The DSP rmware can also be updated via the USB connection. Visit turbosound.com for the latest rmware version.
TSP-AN speakers also oer proprietary ULTRANET networking capabilities through the ULTRANET IN and THRU connections using CAT5 cables with RJ45 connectors.
ULTRANET allows the user to transmit unidirectionally up to 16 independent channels of 24-bit audio throughout the TSP-AN system, as well as other
ULTRANET-equipped devices such as digital mixers and personal monitor systems. Up to 7 devices can be connected in series on a single ULTRANET cable.
MIDAS M32
MIDAS DL16
TSP-AN DSP Menu Structure
Fullrange Subwoofer Function
PROCESS
EQ
None None Sets the frequency response to the default setting.
Live Live Sets the frequency response to a typical live sound setting.
Speech Speech Sets the frequency response for optimal speech intelligibility.
Playback Playback Sets the frequency response ideal for music playback.
User User
Lets you dene your own frequency response setting by
entering the corresponding sub menu.
Sub menu
Low/ High Shelving Low/ High Shelving Lets you dene a low and high shelving lter.
Parametric 1 & 2 Parametric 1 & 2
Lets you dene a parametric bell-type EQ
(Frequency, Qual. and Gain).
XOVER
None - Unit is set for default full range / subwoofer reproduction.
HP 120 Hz LP 120 Hz
Preset with 120 Hz 24 dB / octave lter for crossover
between subwoofer and full-range speakers.
HP 100 Hz LP 100 Hz
Preset with 100 Hz 24 dB / octave lter for crossover
between subwoofer and full-range speakers.
- TSP122
Preset with ideal settings for use in combination with
TSP122 fullrangespeaker.
- TSP152
Preset with ideal settings for use in combination with
TSP152 fullrangespeaker.
TSP118B - Preset with high pass alignment for TSP118B subwoofer.
User User
User crossover sub menu for combination with other
fullrange or subwoofer speaker systems
Sub Menu
Freq Freq
Select the desired crossover frequency:
Fullrange systems: 75 Hz to 400 Hz
Subwoofer systems: 50 Hz to 150 Hz
Phase Phase Adjust the absolute phase (0° or 180°).
FBQ
Auto Auto
Automatically sets as many lters as required. Whenever a
new feedback frequency is discovered, the rst lter will be
released to attenuate the new frequency, and so forth.
Single Single
Activates the FBQ (feedback detection) functionality,
up to 8 feedback lters
Learn Learn
Automatic procedure which searches for feedback frequencies
and locks settings after all 8 lters have been set.
WARNING!
Please use ear protection during
this procedure. The feedback signal
may approach the system’s maximum
level, which may cause hearingdamage!
Reset Reset Resets all lters.
SETUP
(page 1)
INPUT
Input Input
Lets you choose the audio input source. Choose between
Local (analogue Input) or ULTRANET (e.g.,P16 monitoring
system or M32audio via ULTRANET).
Volume Volume
Adjusts the input gain. With ULTRANET digital inputs over
a range from+ 10 dB to - 30 dB. With analogue input from
0 dB to -∞ dB.
Sensitivity Sensitivity
Adjusts input sensitivity for maximum output when using
an analogue source +4 dBu for normal operation,
+ 14 dBu for high level input.
POSITION
Stand Floor
For positioning the speaker on a pole mount stand
(fullrange) or on the oor (subwoofer).