Use the primary connector when using a star network topology, consisting of individual Cat-5e connections between
the devices and an Ethernet switch. Alternatively this connection can be used to daisy chain directly to another Lake
Processor. The daisy chain topology should not be used with Dante.
For a technical reference of the Ethernet Port, please refer to the 20000DP Operation Manual. Additional information
is available in the Lake Network Configuration Guide.
The Ethernet ports operate at the Ethernet data rate of
100 Mbps, and allow straight or crossed network
cables. Two LEDs above each port indicate valid
network connection (LINK) and network activity (ACT).
10.2.1.7 Secondary Connector
The secondary network connector can be used to daisy-chain multiple 20000DPs, LM 26 and legacy Lake devices.
Alternatively, a Dante dual-network topology can be created by connecting all secondary network connectors to a
separate Ethernet switch, ensuring full redundancy in the event of a network component failure.
Additional processor configuration is required for a
dual redundant network setup. See the Lake
Controller Operation Manual for further details.
For a technical reference of the Ethernet Port, please refer to the 20000DP Operation Manual. Additional information
is available in the Lake Network Configuration Guide.
When connecting multiple devices to an Ethernet
network, care must be taken NOT to create a closed
loop which causes network malfunction.
10.2.1.8 Mains Power Connector
The mains power AC input is via a Neutrik powerCON connector, rated at 32 A. The power supply must be
connected to AC mains using a power cable with a correctly wired plug for the country of operation.