4. Connecting the Loudspeakers
4.1 Wiring convention
CONFIGURED FOR TFS-900H CONFIGURED FOR 4-WAYCONFIGURED FOR TFS-900B/L
4.2 Damping Factor in cable
Turbosound recommends that for large scale PA use the total system damping factor should be 15 or greater. Longer
cables will reduce the overall damping factor of the system. In order to keep the damping factor over 15 it will be
necessary to increase the impedance of the load to keep the damping factor. Therefore for long runs Turbosound
recommends no more than two enclosures per amplifier. Turbosound recommends using 4mm
2
cable as standard.
Cable size
mm
2
Length for 1 x TFS-900H (8 ohms)
m ft
Length for 2 x TFS-900H (4 ohms)
m ft
Length for 3 x TFS-900H (2.6 ohms)
m ft
2.5 38 125 18 59 12 39
4 60 197 30 98 20 66
6 90 295 45 148 30 98
4.3 Power Output Performance
Symmetrical Power
The 20000DP can deliver power as shown in the table below when all channels are driven equally.
Load Impedance (ohms) 2.0 2.7 4 8 16
20000DP Max power output (watts) 4800 5000 4440 2300 1150
Asymmetrical Power
Load Impedance (ohms) 2.0 2.7 4 8 16
20000DP Max power output (watts) 5000 5000 4500 2300 1150