Product Information Document
10 of 15
Product Information Document
Arrayable 2500 Watt 2 Way 15" Loudspeaker
with Dendritic Waveguide, KLARK TEKNIK DSP
Technology and ULTRANET Networking,
90° H x 60° V Dispersion (White)
Install
ATHENS
TC S 152/96 -AN -WH
Technical Specications
System
Frequency response
41 Hz – 18 kHz ±3 dB
35 Hz – 20 kHz -10 dB
Nominal dispersion
90° H x 60° V @ -6 dB points, rotatable
Maximum SPL
133 dB peak
Crossover type
Active
Transducers
1 x 15" (394 mm) LFDriver
1 x 1.4" (36 mm) HF compression driver
Limiter
Independent HF, LF, peak and rms
Amplier
Maximum output power*
2500 W
Type
Class-D
Protection
Short circuit, thermal
Connectors
Input/link
1 x Combo Jack/XLR 1x XLR
Sensitivity +4dBu or +14 dBu software switchable
Input impedance 40 k balanced
Maximum input level +22 dBu
Ultranet input/link
2 x RJ45
Mains supply
Neutrik powerCON 20A†
Controls
DSP
Rotary push-encoder and level control
Buttons for Process, Setup, Exit, Enter
User DSP Functions
Factory EQ presets
Positioning, Sound mode, FBQ
Display
LCD 128 x 32, blue, backlit
Delay
0 - 300 ms
Equalisation
High and low shelvingEQ
2 x parametric EQ
Limiter
Zero attack input limiter
Presets
20 total presets,
19 user-denable
Crossover
High Pass L-R 24 dB/oct
Protection
Lock-out function for all settings
Ultranet Digital Network
Digital processing
A/D conversion 24-bit,44.1/48kHz sample rate
Converter type 24-bit,delta-sigma
System
Signal 16 channels
Latency < 0.9 ms
Frequency response 20 Hz to 20 kHz (+0 / -3 dB)
Dynamic range typical 92 dB
Cabling
Cables Shielded CAT5
Cable length max. 246 ft / 75 m recommended