Quick Start Guide
14 TCS-AN SERIES Quick Start Guide 15
TCS-AN DSP Menu Structure
Fullrange Subwoofer Function
PROCESS EQ
None None Sets the frequency response to the default setting.
Array2 –
Sets a corrected frequency response for 2 cabinets
arrayed together.
Array3 –
Sets a corrected frequency response for 3 or more
cabinets arrayedtogether.
User User
Lets you dene your own frequency response setting
by entering the corresponding sub-menu.
Sub menu
Low/ High Shelving Low/ High Shelving Lets you dene a low and high shelving lter.
Parametric 1 & 2 Parametric 1 & 2
Lets you dene a parametric bell-type EQ (Frequency,
Qual. and Gain).
XOVER
None – Unit is set for default full-range reproduction.
HP 100 Hz LP 100 Hz
Preset with 100 Hz, 24 dB/octave lter for crossover
between subwoofer and full-range speakers.
HP 120 Hz LP 120 Hz
Preset with 120 Hz, 24 dB/octave lter for crossover
between subwoofer and full-range speakers.
User User
User crossover sub menu for combination with other
full-range or subwoofer speaker systems
Sub Menu
Freq Freq
Select the desired crossover frequency:
• Fullrange Systems: 75 Hz to 400 Hz.
• Subwoofer Systems: 50 Hz to 150Hz.
Phase Phase Adjust the absolute phase (0° or 180°).
FBQ
Auto Auto
Automatically sets as many lters as required.
Whenever a new feedback frequency is discovered,
the rst lter will be released to attenuate the new
frequency, and so forth.
Single Single
Activates the FBQ (feedback detection) functionality,
up to 8 feedback lters.
Learn Learn
Automatic procedure which searches for feedback
frequencies and locks settings after all 8 lters have
been set.
WARNING!
Please use ear protection during this procedure. The
feedback signal may approach the system's maximum
level, which may cause hearing damage!
Reset Reset Resets all lters.
SETUP
(page 1)
INPUT
Input Input
Lets you choose the audio input source. Choose
between Local (analogue Input) or ULTRANET
(e.g.,P16 monitoring system or M32 audio via
ULTRANET).
Volume Volume
Adjusts the input gain. WithULTRANET digital inputs
over a range from + 10 dB to - 30 dB. With analogue
input from 0 dB to - ∞ dB.
Sensitivity Sensitivity
Adjusts input sensitivity for maxium output when
using an analogue source +4 dBu for normal
opperation, +14dBu for high level input.
Fullrange Subwoofer Function
POSITION
Free –
For positioning the speaker in free suspension or
ground stacked away from walls.
Wall Floor
For positioning the speaker on or next to a wall, or on
the oor (subwoofer)
Ceiling Wall
For positioning the speaker near the ceiling and wall,
or oor and wall (subwoofer)
Corner Corner
For positioning the speaker in a corner next to the
ceiling (xed install) or in a corner on the oor
(subwoofer)
Screenshot update
DELAY
Delay Delay
Adjusts the amount of delay (max300msec = 103 m
or 338 feet).
Unit Unit Selects between msec, metersandfeet.
LIMITER
Limit Limit
Adjust the limiter threshold for the input signal (from
OFF up to -30 dB). This threshold adjustment allows
you to set a max output power which is below the
loudspeaker system’s rated maxoutput.
SETUP
(page 2)
Version Version Displays the installed rmwareversion.
LOAD
1. - 20. 1. - 20.
To load a specic preset, turn the encoder to select
the desired preset's number, and then press either
the ENTER button or the encoder. Whenasked to
conrm press the encoder again or EXIT to abort.
SAVE
1. - 20. 1. - 20.
To save a preset choose the respective preset slot and
press ENTER or theencoder.
Sub Menu
Save Preset Save Preset
Name the preset by choosing the characters with
the encoder and pressing to conrm each character.
When nished, press the ENTER button to save the
preset.
SETUP
Contrast Contrast
Adjust LCD panel contrast. The default contrast value
is 15.
Screen Screen
ON: LCD screen saver (default) turns on automatically
after approx.2minutes.
OFF : LCD turns o automatically after approx. 5
minutes.
Sub Menu
Lock Lock
Lock the device and create a password by choosing
the password characters with the encoder and
pressing to conrm each character. When nished
press the ENTER button. Unlock the device by
entering the password or connecting the unit via USB
to a PCrunning proprietary remote software. The
software does not require apassword.
Warning Warning
In case of overheating, an alert appears on the LCD
screen, and the amplier will shut down until the
unit cools