Technical Specications
NuQ152-AN (WH) NuQ115B-AN (WH) NuQ118B-AN (WH)
System
Frequency response
55 Hz – 18 kHz ±3 dB
50 Hz – 20 kHz -10 dB
45 Hz – 150 Hz ±3 dB
38 Hz – 200 Hz -10 dB
40 Hz – 150 Hz ±3 dB
33 Hz – 150 Hz -10 dB
Nominal dispersion 70° H x 70° V @ -6 dB points Half Space Half Space
Maximum SPL 133 dB peak 135 dB peak 136 dB peak
Crossover type Active Active Active
Transducers
1 x 15" (393.5 mm) LF driver
1 x 1" (25.4 mm)
HF compression driver
1 x 15" (387 mm) LF driver 1 x 18" (460 mm) LF driver
Limiter
Independent HF, LF,
peak and rms
Peak and rms Peak and rms
Amplier
Maximum Output Power* 2500 W 3000 W 3000 W
Type Class-D Class-D Class-D
Protection Short circuit, thermal Short circuit, thermal Short circuit, thermal
Connectors
Input/link 1 x combo jack/XLR, 1 x XLR 1 x combo jack/XLR, 1 x XLR 1 x combo jack/XLR, 1 x XLR
Sensitivity +4dBu or +14 dBu software switchable +4dBu or +14 dBu software switchable +4dBu or +14 dBu software switchable
Input impedance 40 k balanced 40 k balanced 40 k balanced
Maximum input level +22 dBu +22 dBu +22 dBu
Ultranet input/link 2 x RJ45 2 x RJ45 2 x RJ45
Mains Supply Neutrik powerCON 20A Neutrik powerCON 20A Neutrik powerCON 20A
Controls
DSP
Rotary push-encoder and levelcontrol
Buttons for process, setup, exit, enter
Rotary push-encoder and levelcontrol
Buttons for process, setup, exit, enter
Rotary push-encoder and levelcontrol
Buttons for process, setup, exit, enter
User DSP Functions
Factory EQ Presets Positioning, sound mode, FBQ Positioning, sound mode Positioning, sound mode
Display LCD 128 x 32, blue, backlit LCD 128 x 32, blue, backlit LCD 128 x 32, blue, backlit
Delay 0 - 300 ms 0 - 300 ms 0 - 300 ms
Equalisation
High and low shelving EQ
2 x parametric EQ
High and low shelving EQ
2 x parametric EQ
High and low shelving EQ
2 x parametric EQ
Limiter Zero attack input limiter Zero attack input limiter Zero attack input limiter
Presets
20 total presets,
19 user-denable
20 total presets,
19 user-denable
20 total presets,
19 user-denable
Crossover High pass L-R 24 dB/oct Low pass L-R 24 dB/oct Low pass L-R 24 dB/oct
Protection Lock-out function for allsettings Lock-out function for allsettings Lock-out function for allsettings
Ultranet Digital Network
Digital processing
A/D conversion 24-bit,44.1/48kHz sample rate 24-bit,44.1/48kHz sample rate 24-bit,44.1/48kHz sample rate
Converter type 24-bit, delta-sigma 24-bit, delta-sigma 24-bit, delta-sigma
System
Signal 16 channels 16 channels 16 channels
Latency < 0.9 ms < 0.9 ms < 0.9 ms
Frequency response 20 Hz to 20 kHz (+0 / -3 dB) 20 Hz to 20 kHz (+0 / -3 dB) 20 Hz to 20 kHz (+0 / -3 dB)
Dynamic range Typical 92 dB Typical 92 dB Typical 92 dB
Cabling
Cables Shielded CAT5 Shielded CAT5 Shielded CAT5
Cable length Max. 246 ft / 75 m recommended Max. 246 ft / 75 m recommended Max. 246 ft / 75 m recommended
NuQ152-AN (WH) NuQ115B-AN (WH) NuQ118B-AN (WH)
Power Supply
Power consumption 90 W @
⁄
max power 180 W @
⁄
max power 180 W @
⁄
max power
Voltage (fuses)
USA / Canada 120 V~, 60 Hz (T 15 A H 250 V) 120 V~, 60 Hz (T 15 A H 250 V) 120 V~, 60 Hz (T 15 A H 250 V)
UK / Australia / Europe
220-240 V~, 50/60 Hz
(T 10 A H 250 V)
220-240 V~, 50/60 Hz
(T 10 A H 250 V)
220-240 V~, 50/60 Hz
(T 10 A H 250 V)
Korea / China
220-240 V~, 50/60 Hz
(T 10 A H 250 V)
220-240 V~, 50/60 Hz
(T 10 A H 250 V)
220-240 V~, 50/60 Hz
(T 10 A H 250 V)
Japan
100 V~, 50/60 Hz
(T 15 A H 250 V)
100 V~, 50/60 Hz
(T 15 A H 250 V)
100 V~, 50/60 Hz
(T 15 A H 250 V)
Enclosure
Dimensions HWD
712 x 430 x 385 mm
(28.0 x 16.9 x 15.2")
520 x 580 x 620 mm
(20.4 x 22.8 x 24.4")
770 x 580 x 700 mm
(30.3 x 22.8 x 27.5")
Net weight 23.6 kg (52.0 lbs) 37 kg (81.5 lbs) 57.9 kg (127.6 lbs)
Construction 15 mm (
⁄
") birch plywood 18 mm (¾") birch plywood 18 mm (¾") birch plywood
Finish Semi matt black paint Semi matt black paint Semi matt black paint
Grille Powder coated perforatedsteel Powder coated perforatedsteel Powder coated perforatedsteel
Flying hardware M10 x 8 points M10 x 16 points M10 x 16 points
Accessories
NUQ152-FY ying yoke forNuQ152
*independent of limiters and driver protection circuits
Only qualied personnel are allowed to modify the AC-Main cord and to adhere to all applicable national standards.