TurboChef Technologies Inc. Tornado and Tornado 2 (NGC) Ventless Submittal Information 1. Spec Sheets 1.1 2. UL Ventless Label 2.1 3. UL Listing 3.1 4. UL KNLZ Explained 4.1 5. Test Report 5.1 6. KNLZ Letter 6.1 7. Mechanical Code Sections 7.1 8. Emissions by Product 8.1 9. Fire and Smoke Statement 9.1 10. Heat Loading Calculations 10.1 11. Sampling of Letters from the Following States/Jurisdictions 11.1 California 11.1 North Carolina Department of Insurance 11.
Item No.
26” (660 mm) 25.7” (653 mm) Tornado ® 19” (483 mm) 23” (584 mm) 11.25” (286 mm) Dimensions Single Units Max Circuit Requirement 20 amp Plug IEC 309, 5-pin, 32 amp Height 19” 483 mm Max Input 10500 watts on legs 23” 584 mm Microwave Input Power 3500 watts Width 26” 660 mm Depth 25.7” 653 mm Phase 3 Phase with handle 28.2” 716 mm Voltage 230 VAC 190 lbs.
Item No.
TORNADO 2 TM 26” (660 mm) 19” (483 mm) 25.7” (653 mm) 23” (584 mm) 11.5” (292 mm) DIMENSIONS Single Units Plug IEC 309, 5-pin, 32 amp Max Input 10,500 watts 3,500 watts Height 19” 483 mm Microwave Input Power on legs 23” 584 mm NGCED (NGC-1280-1D) Width 26” 660 mm Phase 3 Phase Depth 25.7” 653 mm Voltage 230 VAC with handle 28.45” 723 mm Frequency 50 Hz Weight 190 lb.
Page 2.
KNLZ.E151487 - Commercial Cooking Appliances with Integral Systems for Limiting the Emission of ... Page 3.1 KNLZ.
KNLZ.GuideInfo - Commercial Cooking Appliances with Integral Systems for Limiting the Emission of... Page 4.1 KNLZ.
KNLZ.GuideInfo - Commercial Cooking Appliances with Integral Systems for Limiting the Emission of... Page 4.2 Last Updated on 1999-02-19 Questions? Notice of Disclaimer Page Top Copyright © 2008 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service.
Page 5.
Page 5.
Page 6.1 April 10, 2007 Mr. James Pool Turbochef Technologies Inc Suite 105 4240 International Pky Carrollton, TX 75007 United States Our Reference: File E151487 Subject: INTEGRAL RECIRCIRCULATING SYSTEM Dear Mr. Pool: In reply to your e-mail message received today, I offer the following. Products in the KNLZ category (as well as KNKG) are evaluated to UL710B. It used to be that UL197 and supplement SB in UL197 was the standard that they were evaluated to.
Page 7.1 EXHAUST SYSTEMS EXHAUST SYSTEMS air from the exhaust outlet discharges away from such locations. 506.4 Ducts serving Type II hoods. Single or combined Type II exhaust systems for food-processing operations shall be independent of all other exhaust systems. Commercial kitchen exhaust systems serving Type II hoods shall comply with Sections 506.4.1 and 506.4.2. 506.4.1 Type II exhaust outlets. Exhaust outlets for ducts serving Type II hoods shall comply with Sections 401.4 and 401.4.2.
Page 8.1 UL 710B (KNLZ) Emissions by Product 275 3 250 2.75 2.5 2.25 200 2 175 1.75 150 1.5 125 1.25 100 1 75 0.75 50 Pizza's Cooked Emissions 25 0.5 0.
Page 9.1 October 18, 2004 Mr. Mike Denny Building Services, 224 West Knight St. City of Sioux Falls, South Dakota, 57102 Ph: 605-367-8252 Re: Fire and smoke containment Dear Mr. Denny: The TurboChef ovens have been extensively tested and conform to UL 923 and UL KNLZ standards. The UL 923 standard is the electrical/product safety standard and the KNLZ is the low particulate matter emissions standard to which we conform.
Page 9.2 Test Method: The UL KNLZ category requires that products must have less than 5.0 mg/m3 of particulate matter emissions during 8 continuous hours of cooking a “worst case” food product as measured by EPA 202. Note: Our products were tested using full-fat pepperoni pizzas. As it pertains specifically to smoke: Smoke typically consists of visible grease particulate that escapes from a product during operation.
Page 10.1 NGC Energy.xls NGC Tornado (1 PHASE) Changeable Parameters Operating Time Energy Costs Snooze Mode Cook Cycles/Day Typical Cook Time 12 $0.11 0.00 100 Hours kWHr Hours Cooks/Day 60 Seconds Time (min) Power (Watts) Cost/Day Balance of Time (hrs) 15 100 0 605 5277 5000 1100 1400 $0.15 $0.96 $0.00 $1.62 11.75 10.08 10.08 0 $2.72 $81.72 Yearly $980.
Page 11.1 State of California—Health and Human Services Agency 3 Department of Health Services ARNOLD SCHWARZENEGGER Governor SANDRA SHEWRY Director July 23, 2004 Ruth Sender OhCal Foods, Inc. 20501 Ventura Blvd., Suite 375 Woodland Hills, CA 91364 RE: Exemption from Mechanical Exhaust Ventilation for TurboChef Model NGC Rapid Cook Oven Dear Ms.
Page 11.2 Ms. Ruth Sender July 23, 2004 Page 2 3. The oven shall not be used for cooking meats, poultry, fish, or other foods that may produce grease laden vapors. Such use will require that mechanical ventilation be installed over the unit. 4. The oven must be operated and installed in a well-ventilated area approved for food preparation. 5. The oven must be installed, maintained, operated, and serviced according to the specifications of the manufacturer and local codes. 6.
Page 11.3 Ms.
Page 11.4 State of California—Health and Human Services Agency Department of Health Services Food & Drug Branch DIANA M. BONTÁ, R.N., Dr. P.H. Director GRAY DAVIS Governor October 25, 2002 Peter J. Ashcraft TurboChef Technologies, Inc. 10500 Metric Drive, Suite 128 Dallas, Texas 75243 Dear Mr.
Page 11.5 Peter Ashcraft October 25, 2002 This exemption shall be in effect until revoked. However, should any local enforcement agent find that the operation of the TurboChef Technologies Model C3/C Rapid Cook Oven without mechanical ventilation creates a sanitation or safety problem, the local enforcement agent may require the unit to be used only with external mechanical ventilation.
Page 11.
Page 11.
Page 11.
Page 11.9 Evaluation # 200424-H Revision 2 Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Wisconsin Building Products Evaluation Material Manufacturer Microwave Oven TurboChef Model NGC TurboChef Technologies, Inc. 10500 Metric Dr., Suite 128 Dallas, TX 75243 SCOPE OF EVALUATION Section 507.2.
Page 11.10 COMMERCE Product Evaluation No. 200424-H Revision 2 Page 2 Exception: 3. A single light-duty electric convection, bread, retherm or microwave oven designed for installation on a counter or that is enclosed on five sides in a counter, provided that such appliances do not increase the ambient temperature more than 10º F at a distance greater than 5 feet away from such appliance during operation.
Page 11.
Page 11.12 JENNIFER M. GRANHOLM GOVERNOR STATE OF MICHIGAN DEPARTMENT OF AGRICULTURE LANSING DAN WYANT DIRECTOR April 14, 2004 Mr. James Boyd, Plan Review Specialist Kent County Health Department Environmental Health Division 700 Fuller Avenue, N.E. Grand Rapids, MI 49503 Re: Turbo-Chef Convection / Microwave Oven Models C3/C and NGC Dear Mr. Boyd: You requested an evaluation of the Turbo Chef oven model NGC, that is proposed to be installed in Subway restaurants state-wide.
Page 11.
Page 11.
Page 11.
Page 11.
Page 11.17 HI|IFÐtr BiffLMHG À!*Ð 5AfËTY €ûÉ{tftssÍ01{,f Rs C¡rv rF Los ANc=r-=s IEFX¡*rr B C*,LIFORFIIÅ I'ILE}Ii{G ¡Ë.1 filÅ*sf{i\TÐ,R$w,¡l FñËffi${T ì/åù,¡ AldE.É\¡ELt5 VtrPëSS9E¡IIT ATËE} SÂF:ETV I{TETH FIG{.EROÅ STFÉET LWAI,¡GEI-ES. CA Ðtr ROÊ:f RT R. "EUÐF 01¡.RtM GEiEtr\¡- IS{HÂGER VICTÐ'R H. CUEVÀ5 HELEHAJ UB,AT'IY E LtlJ ûRE ll ì¡"dlLLtALlS RAY¡,i0t'tÐs. 0HAN, c.E., s.Ë.. ¡ts4uTir"= C!E:F. *NTC}NI O R VILLÀR¡.,ITÛSA !,t.
z Axorl¡s a I Couxw A{. Prhlio HeAItlt r ¡rrrr \\ oF Los ' , JONATHAN E. FIELDING, M.D., M.P,H. BOARD OF SUPERVISORS D¡rector and Health Officer Gloria Molina JONATHAN E. FREEDMAN First Distr¡ct Chief Deputy Director Mark R¡dley-Thomas ANGELO BELLOMO, R.E.H.S., Director Zev Yaroslavsky Second D¡str¡ct Environmental Health Th¡rd Distr¡ct Don Knabe VERONICA BAUCHMAN, R.E,H.S. Fourth Distr¡ct Act¡ng Director, Bureau of District Surveillance and Enforcement M¡chaèl D.
Page 11.19 TurboChef Oven May 3I,20lI Page2 of3 Therefore, additional mechanical ventilation in the form of a Type I or Type II hood is not required by the County of Los Angeles Department of Public Health, provided the following contingencies are met: L There shall be no more than two unventilated model Tomado (NGC) or Tornado 2 (NIGCD6) oven per food facility. 2. No other heat producing food related equipment requiring ventilation shall be t the addition of mechanicai ventilation. 3.
Page 11.20 TurboChef Oven May 31,2071 Page 3 of3 This exemption shall be in effect for a period of five years from the date of this letter, or until revoked. However, this exemption shall not preclude this Department from requiring the installation of mechanical exhaust ventilation when operation of the Tomado or Tornado 2 oven at a specific location results in a sanitation or safety violätion.
Page 12.1 T URB O C HE F TE C HNOLOGI E S, I N C. Tornado 2 Oven Surface Temperatures TM (271°C) for the duration of the test.
Page 12.