Electric Oven Service Manual
Accessing the Fault Count Screen
Refer to page 29 for fault descriptions.
From the
CONFIG MODE (Figure 9, page 15),
press R1 to access the fault count screen (Figure
13). The oven will display the number of faults
that have occurred since the oven fault counts
were last cleared (page 20), the oven’s software
was last updated (page 15), or the oven was last
returned to the manufacturer’s default settings
(page 20).
Accessing the Setup Mode
From the CONFIG MODE (Figure 9, page 15),
press L1 to access the
SETUP MODE. The SETUP
MODE
allows the user to customize several oven
settings - see below for more details.
Accessing the Test Mode
From the CONFIG MODE (Figure 9, page 15),
press R3 to access the
TEST MODE. The TEST
MODE
gives the service agent the ability to
diagnose oven problems and perform other serv-
ice related tasks. See page 17 for more informa-
tion on the
TEST MODE.
Setup Mode
Figure 14
The SETUP MODE serves four main purposes:
1. To change the display temperature.
2. To access the edit option screen.
3. To change the display language.
4. To access the info screen.
To access the SETUP MODE, press the up key
from the
OVEN OFF or COOLING DOWN MODE
(to access the CONFIG MODE), and then press L1.
Changing the Display Temperature
The oven can display the temperature in either
Celsius or Fahrenheit units. To change the
display temperature, press L1 in
SETUP MODE
(Figure 14).
Edit Option Screen
The edit option screen (Figure 16) allows the
user to switch between full edit, rigid, and flex
options. For more information on the different
edit options, see Editing a Cooking Profile on
page 12.
To access the edit option screen,
1. Press L3 (Figure 14) to access the password
screen (Figure 15).
2. Input the password 6 6 3 3 by pressing the
soft key adjacent to the appropriate number.
To change the edit option (Figure 16),
-Press L1 to select the full edit option.
-Press L2 to select the rigid option.
-Press L3 to select the flex option.
1
2
3
4
5
<6633>
6
ENTER PASSWORD
Figure 15: Password Screen
FULL EDIT*
RIGID
FLEX
EDIT OPTION
Figure 16: Edit Option Screen
DEGS F
EDIT/RIGID/FLEX
ENGLISH
SETUP MENU
INFO
Figure 14: Setup Mode
16 OVEN MODES
F1: 0
F2: 0
F3: 0
F4: 0
F5: 0
F6: 0
F7: 0
F8: 0
F9: 0
F10: 0
FAULT COUNTS
Figure 13: Fault Counts Screen
L1
L2
L3
R1
R2
R3
L1
L2
L3
R1
R2
R3
L1
L2
L3
R1
R2
R3
L1
L2
L3
R1
R2
R3