FOR HYDROCARBON REFRIGERATION UNITS
WARNING
• Handle the unit with care in order to avoid any serious damage to the 
 refrigeration system.
• The refrigerant tubing, condenser, and evaporator coils are easily prone to damage 
  while handling, moving, installing, and cleaning the unit, which may lead to fire or 
 even explosion. 
• Refrigerant squirting out of the pipes could ignite or cause an eye injury. If a leak
  is detected, avoid any naked flames or potential sources of ignition and air the 
  room in which the appliance is standing for several minutes.
• In order to avoid the creation of a flammable gas-air mixture in case of a leak
  in the refrigerating circuit, the size of the room in which the appliance is placed 
  depends on the amount of refrigerant used. The room must be 35.31ft
3 (
1m³) in size 
  for every 0.28oz (8g) of R-600a refrigerant inside the appliance. The amount of 
  refrigerant in your particular appliance is shown on the label inside the cabinet.
• Never start up an appliance showing any signs of damage. If in doubt, contact
  a qualified service professional.
• In case of any hazardous activities such as fire or explosion, move the unit away 
  from any source of ignition to a well ventilated area.
• Further service and repair must be done by a qualified technician who is familiar 
  with the safety standards, and also has thorough understanding and knowledge
  of the flammable refrigerants. 
• Any and all technicians handling these units must be equipped with proper 
  personal protection and equipment and follow applicable safety measures and 
  precautions to avoid risk of fire or explosion.
This appliance contains a small amount of propane (R-290) or 
isobutane (R-600a) refrigerant, a natural gas with high environmental 
compatibility, but it is also combustible. When transporting and 
installing the appliance, care should be taken to ensure that no part 
of the refrigerating circuit is damaged.