Turbo Air Speeds up the Pace of Innovation Glass Door Merchandisers Refrigerators Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment. GLASS DOOR REFRIGERATORS TGM-5R-N# TGM-11RV-N# TGM-14RV-N# TGM-22RV*-N# TGM-35R-N# TGM-48R*-N# TGM-50RS*-N# TGM-69R*-N# TGM-72RS*-N# (*) - May or may not have suffix from A to Z to denote cosmetic difference. (#) - May or may not be followed by a letter indicating refrigerant type. www.turboairinc.
CONTENTS PAGE NOTICE .......................................................................................................................... 3 FOR HYDROCARBON REFRIGERATION UNITS ..................................................... 4 - 5 IMPORTANT SAFETY INFORMATION - SAFETY PRECAUTIONS ........................................................................................... 6 - INSTALLATION & USAGE ...................................................................................
NOTICE • This equipment is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of this equipment and the hazards involved by a person responsible for their safety.
FOR HYDROCARBON REFRIGERATION UNITS WARNING This unit uses R-290 (propane), or R-600a (isobutane) as a refrigerant. These hydrocarbon refrigerants are highly environmentally compatible but also are flammable and combustible. Please read this manual thoroughly before installing and operating the unit. Please take cautious measures to avoid risk of fire or explosion. PLEASE REFER TO THE LABEL INSIDE THE CABINET TO CHECK REFRIGERATION TYPE AND VOLUME. DANGER - Risk of fire or explosion.
FOR HYDROCARBON REFRIGERATION UNITS WARNING • Handle the unit with care in order to avoid any serious damages to the refrigeration system. • The refrigerant tubing, condenser, evaporator coils are easily prone to damage while handling, moving, installing, and cleaning the unit, which may lead to fire or even explosion. • Refrigerant squirting out of the pipes could ignite or cause an eye injury.
IMPORTANT SAFETY INFORMATION SAFETY PRECAUTIONS To avoid any risk of fire, explosion, electric shock, personal injury, material damage or incorrect use of the appliance, be sure to observe the following safety precautions. (After reading these owner’s manual instructions, please keep the manual booklet in a safe place for reference. Remember to hand it over to any subsequent owners) WARNING • The unit must be installed and located in accordance with the manufacturer’s installation instructions.
IMPORTANT SAFETY INFORMATION INSTALLATION & USAGE WARNING • Do not install the unit in a damp place where it could be splashed with water. Incorrect insulation of the electrical parts may cause fire or electric shock. • Do not plug several appliances into the same sockets. This could cause overheating and risk start of a fire. • Keep the power plug away from the rear of the cabinet. A damaged power plug may cause fire due to overheating.
IMPORTANT SAFETY INFORMATION INSTALLATION & USAGE CAUTION • There is a risk of death from suffocation if a child puts the packing materials on his or her head. • Do not store any articles on top of the appliance. Articles may fall while opening or closing the door, and could cause personal injury or material damage. • Do not store pharmaceutical products, scientific materials or other temperature-sensitive products in the refrigerator.
IMPORTANT SAFETY INFORMATION PROPER DISPOSAL OF OLD APPLIANCE For environmental purpose, refrigeration appliances must be disposed of properly. This applies to your old appliance, and at the end of its service life, for your new appliance as well. WARNING Before disposing of old appliances, make them inoperable. Remove plug from mains, severe the power cable, and remove or destroy any snap or latch closures.
SPECIFICATIONS Refrigerators Model Rating Equipment Operating Temp. Class Temp. (℉) (℉) Designation V/Hz Refrigerant AMPS TGM-5R-N# 38(M) ≥32 VCT, SC, M (110-120) V~, 60Hz R-600a / 1.76 oz (50 g) 1.2 A TGM-11RV-N# 38(M) ≥32 VCT, SC, M (110-120) V~, 60Hz R-600a / 2.12 oz (60 g) 2.2 A TGM-14RV-N# 38(M) ≥32 VCT, SC, M (110-120) V~, 60Hz R-600a / 2.12 oz (60 g) 2.2 A TGM-22RV*-N# 38(M) ≥32 VCT, SC, M (110-120) V~, 60Hz R-600a / 2.47 oz (70 g) 2.
NOTICE TO CUSTOMER Loss or spoilage of products in your refrigerator/freezer is not covered by warranty. In addition to following recommended installation procedures, you must run the refrigerator/ freezer 24 hours prior to usage. INSTALLATION 1. LOCATION - Allow adequate space and install the refrigerator on a firm, and level floor. If the appliance is not level, there may be unusual noises and poor cooling performance. 2.
CLEANING Before cleaning, unplug the unit and disconnect the power. Wipe and clean the inside and outside of appliance with a damp cloth. 1. CLEANING THE INTERIOR AND EXTERIOR - The interior and exterior of the unit can be cleaned using warm water with soap. - Do not use an abrasive cleaner because it will scratch the surface. 2. CLEANING THE CONDENSER COIL - To maintain proper refrigeration performance, the Condenser coil must be free of dust, dirt, and grease. This will require periodic cleaning.
BASIC OPERATION 1. The controller(thermostat) is located at the right inside the cabinet. 2. T he factory setting for the control is '3' or '4', and maintains about 37.4°F(3 ℃) inside. 3. T urn the Temperature Controller counter clock wise (or the lower number setting) for warmer temperature, and clock-wise (or the higher number setting) for colder temperature. * Labels for Temperature Controller may differ for various models. Temperature Controller (Thermostat) 4. T he temp.
CAUTION 1. POWER CORD - Be sure the power cord is connected to the proper voltage. - A protected circuit of the correct voltage and amperage must be run for connection of the line cord. - Turn 'off' the power switch before disconnecting the power cord, whenever performing maintenance functions or cleaning the refrigerated cabinet. - Compressor warranties are void if compressor burns out due to low voltage. 2. RESTARTING - If disconnected, wait 5 minutes before restarting. 3.
HOW TO ADJUST A SHELF POSITION AND REPLACE A LAMP (TGM-11RV-N#, TGM-14RV-N#, TGM-22RV*-N#) Disconnect the lamp connecter from the main terminal. - When disconnecting the lamp connector, hold on to the connector. Do not pull by holding on to the wire. MAIN TERMINAL LAMP CONNECTOR LAMP BASE HOLDING BOLT LAMP BASE HOLDER LAMP SOCKET (ONIY LAMP) LED OR LAMP LAMP BASE Detach the lamp base holder from the lamp base.
TROUBLESHOOTING 1. If the appliance does not turn on, check for: - Power failure, - Properly inserted plug, - The power switch is on, - Thermostat setting 2. If the temperature inside the compartments is not low enough, check for: - Closure of the doors, - Installation near a heat source, - Correct setting of the refrigerator / freezer temperature controls, - Inhibited air circulation. - Condenser coil is properly cleaned. 3.
TROUBLESHOOTING SYMPTOMS CAUSES SOLUTIONS Cooler is freezing food. • Thermostat set too cold. • Turn the thermostat setting to a higher temperature position. The unit does not refrigerate at all. • There is a power connection failure problem. • Check the power cord and plug in correctly. The unit does not refrigerate well. • The unit is in sunlight or near a heating device. • The unit contains hot food or too much food. • The unit door is opened too frequently or left open long. • The temp.
WARRANTY INFORMATION TWO (2) YEAR WARRANTY Warranty Claims... All claims for parts or labor must be made directly through Turbo Air. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect. In case of compressor replacement under warranty, either compressor or compressor tag must be returned to Turbo Air along with above listed information.
WARRANTY INFORMATION What is Not Covered by This Warranty... Turbo Air’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty. NO CONSEQUENTIAL DAMAGES.
Turbo air TGM-5R-N#~TGM-72RS_-N#외(영)_미주향.
Turbo air TGM-5R-N#~TGM-72RS_-N#외(영)_미주향.
W 22 Turbo air TGM-5R-N#~TGM-72RS_-N#외(영)_미주향.
Warranty information card must be submitted via post mail or electronically on our website at www.turboairinc.com/registration within 7 days from the date of purchase. Failure to comply may result in your warranty being voided. WARRANTY REGISTRATION CARD MAIL CARD IMMEDIATELY OR GO TO ONLINE REGISTRATION AT www.turboairinc.
4184 E. Conant St., Long Beach, CA 90808 Toll Free: 1-800-381-7770 Fax: 310-900-1033 Email: warranty@turboairinc.com www.turboairinc.com TGM-5R-N#~TGM-72RS_-N#외(영)_미주향.