Turbo Air Speeds up the Pace of Innovation Bakery Cases Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment. TCGB-36-2-*-N TCGB-48-2-*-N TCGB-60-2-*-N TCGB-72-2-*-N TCGB-36-2-UF-*-N TCGB-48-2-UF-*-N TCGB-60-2-UF-*-N TCGB-72-2-UF-*-N TCGB-60-2-CO-*-N TCGB-72-2-CO-*-N www.turboairinc.
CONTENTS PAGE INTRODUCTION 10 SPECIFICATIONS 11 INSTALLATION Damage inspection 12 Location of display Leveling of display OPERATING INSTRUCTIONS 14 Power switch Light switch Temperature control Thermometer Placing the product MAINTENANCE & CLEANING 15 Condenser coil TROUBLESHOOTING 16 Merchandiser not functioning Merchandiser is warm Lights are not working WARRANTY NOTE 17 19~22
NOTICE DANGER, WARNING CAUTION DANGER WARNING CAUTION 3
FOR HYDROCARBON REFRIGERATION UNITS WARNING This unit uses R-290 (propane), or R-600a (isobutane) as a refrigerant. These hydrocarbon refrigerants are highly environmentally compatible but also are flammable and combustible. Please read this manuel thoroughly before installing and operating the unit. Please take cautious measures to avoid risk of fire or explosion. PLEASE REFER TO THE LABEL INSIDE THE CABINET TO CHECK REFRIGERATION TYPE AND VOLUME. DANGER - Risk of fire or explosion.
FOR HYDROCARBON REFRIGERATION UNITS WARNING
IMPORTANT SAFETY INFORMATION SAFETY PRECAUTIONS WARNING
IMPORTANT SAFETY INFORMATION INSTALLATION & USAGE WARNING CAUTION
IMPORTANT SAFETY INFORMATION INSTALLATION & USAGE CAUTION
IMPORTANT SAFETY INFORMATION PROPER DISPOSAL OF OLD APPLIANCE For environmental purposes, refrigeration appliances must be disposed of properly. This applies to your old appliance, and at the end of its service life, for your new appliance as well. WARNING Before disposing of old appliances, make them inoperable. Remove plug from mains, severe the power cable, and remove or destroy any snap or latch closures.
INTRODUCTION This owner’s manual has important information. Please read the entire manual before installing your new Turbo Air Open Display Merchandiser. For specific questions not answered on this manual, please call: CUSTOMER SERVICE DEPARTMENT TURBO AIR 4184 E. Conant St. Long Beach, CA 90808 1-800-381-7770 Please write down the model and serial number of your merchandiser for future references: MODEL NUMBER SERIAL NUMBER WARNING Keep this manual in a safe place for your reference.
SPECIFICATIONS Model TCGB-36-2-*-N TCGB-48-2-*-N TCGB-60-2-*-N TCGB-72-2-*-N TCGB-36-2-UF-*-N TCGB-48-2-UF-*-N TCGB-60-2-UF-*-N TCGB-72-2-UF-*-N Dimension (W x D x H) in. 36.5 x 34.2 x 50.2 48.5 x 34.2 x 50.2 60.5 x 34.2 x 50.2 72.5 x 34.2 x 50.2 Electricity 115V/1PH/60HZ Full Load Amperes 7.5A 7.5A Compressor 8.6A NEK6210U NEU6217U Refrigerant Lighting R-290 11.6W X 3 8.4W X 3 Defrost Net Weight 8.6A 14.7W X 3 17.9W X 3 Timed off defrost 525 lbs. 417 lbs. 699 lbs. 584 lbs.
INSTALLATION INSTRUCTIONS DAMAGE INSPECTION Prior to installation, the customer must check for damages with the freight company before the unit is accepted. 1. If the crate is damaged, make sure to note the damage on the Bill of Lading prior to signing the delivery off. 2. Concealed damage must be reported within 5 days of receiving the unit. Bill of Lading must be faxed to the Claims department. Pictures of both unit and crating may be requested.
Turbo Air Recommended Operating Conditions Units should not be placed in direct sunlight. Units should not be placed near HVAC vents. Units should not be placed near fans. DOOR LEVEL Level the cabinet on all four corners of the base. Units should not be placed near doorways. 12” 305mm 4“ 102mm Confirm there is enough clearance for proper air circulation 75එ (23) and 55% humidity Operating environment not to exceed 75එ (23) and 55% humidity.
OPERATING INSTRUCTIONS Level and set your merchandiser in place. Connect all necessary electrical connections. Your Open Display Merchandiser should now be ready for use. POWER SWITCH: Located at the bottom of rear panel right. LIGHT SWITCH: Located at the bottom of rear panel right. TEMPERATURE CONTROL: Located at the bottom of rear panal right. HOW TO SET THE TEMPERATURE 1. Press the SET button for 1S to check the temperature setting. 2. The display panel shows the current temperature setting.
MAINTENANCE & CLEANING Always turn off your unit (both power and lights) when cleaning. Remove all products and allow your unit to reach room temperature. Do not allow electrical components to get wet. CLEAN YOUR OPEN DISPLAY MERCHANDISER THOROUGHLY BEFORE FIRST USAGE. a. Do not clean with harsh detergents. Use mild soap. b. Remove all products. c. Remove shelves and bottom trays. d. Clean interior with warm water and mild detergent. e. Wipe with damp cloth. Do not leave soap residue.
TROUBLESHOOTING For any problems with your unit, please refer to the following check list. If you are still experiencing problems or have questions, please call the Customer Service line at 1-800-381-7770. Ⳓ MERCHANDISER NOT FUNCTIONING a. Check to see that the breaker hasn’t tripped. b. Check that enough power is BEING supplied to the unit. c. Check that the power switch is on. ⳓ MERCHANDISER IS WARM a. Check the condenser to see if it is clean. b.
22
22
22
22