ManualsBrandsTurbo Air ManualsCommercial EquipmentPRO-26H-G-PT-LR 29" Pro Series Front Left and Back Right Hinged Glass Door Pass-Thru Heated Cabinet with 26.2 cu. ft. Capacity, Digital Temperature Control & Monitor System, Ducted Fan Air Distribution System and LED Lighting in Stainless Steel - 115 Volt
15
TROUBLESHOOTING
The unit is not
operating.
The unit is
not holding
temperature. 
The unit is
overheating.
There is
a loud noise.
The door does not
close tightly.
• Power cord is unplugged.
• Fuse is blown.
• Improper voltage is supplied
 to cabinet.
• Power switch is turned off.
• The unit is not pre-heated
 before use.
• The unit contains cold food
 or too much food.
• The door is opend too
  frequently or left open long. 
• Temperature is set too low.
• Improper voltage is supplied
 to cabinet. 
• Fan motor is not operating or
 air duct is restricted.
• Temperature is set too high.
• The floor is too weak or the
 leveling feet is set incorrectly. 
• The tray is not in the correct
 position.
• The door is bent.
• The unit is a leveling failure.
• The door gasket has come out.
• Check the power cord and
 plug in it correctly. 
• Replace fuse.
• Correct the supply voltage.
• Turn on the power switch.
• Turn the unit on 24 hours
 before use. 
• Check the condition of
 stored food.
• Keep the door closed when
 not in use.
• Raise the temperature
 set value. 
• Correct the supply voltage.
• Check the fan motor and air
 duct for proper air flow.
• Lower the temperature set
 value.
• Check the installation and
 adjust the tray position. 
• Level the unit again.
• Reposition the gasket.
SYMPTOMS CAUSES SOLUTIONS