Thermal-Disc & Thermostatic Traps
Thermostatic Radiator Steam Traps -
Series TA
Model No. Pipe Size A B C D E Weight
TA-1/2-A
1/2” Angle 3.00 1.25 2.57 2.56 -- 1.75 lbs
TA-3/4-A
3/4 Angle 3.38 1.37 2.87 2.56 -- 1.84 lbs
TA-1-A
1” Angle 4.13 2.00 4.12 2.08 -- 2.50 lbs
TA-1/2-S
1/2” Straight 3.00 2.15 3.00 2.50 1.00 1.94 lbs
TA-3/4-S
3/4” Straight 3.38 2.15 3.00 2.50 1.00 2.05 lbs
TA-1/2x3/4-A
1/2” x 3/4” Angle 3.38 1.25 2.57 2.56 -- 1.75 lbs
TA-1/2-V
1/2” Vertical 2.50 4.85 -- -- -- 1.65 lbs
Capsule
TCTA-2901
TCTA-2901
TCTA-2904
TCTA-2901
TCTA-2901
TCTA-2901
TCTA-2901
Angle Pattern (A)
Straight Pattern (S) Vertical Pattern (V)
Engineering Specifications
CAPACITIES
*
DIFFERENTIAL PRESSURE (PSI)
Square Feet EDR**
lbs Condensate
per hour***
Model
Size
NPT
PSIG
Orifice
1/2 1 1-1/2 2 5 10 25 50 75 125
TA-1/2-A
1/2” 5/16 120 165 200 230 320 500 825 1400 1700 1950
TA-3/4-A
3/4” 5/16 230 330 400 465 730 1050 1700 2375 2680 3300
TA-1-A
1” 1/4 430 590 700 760 1200 1750 4100 4050 4700 5500
TA-1/2x3/4-A
1/2”x3/4” 5/16 230 330 400 465 730 1050 1700 2375 2680 3300
TA-1/2-S
1/2” 5/16 120 165 200 230 320 500 825 1400 1700 1950
TA-3/4-S
3/4” 5/16 230 330 400 465 730 1050 1700 2375 2680 3300
TA-1/2-V
1/2” 5/16 120 165 200 230 320 500 825 1400 1700 1950
* Ratings are in accordance with standards established by The Steam Heating Equipment Manufacturers Association (SHEMA). No safety factor required.
** To convert Square Feet EDR to pounds of condensate per hour: Divide the square foot ratings by 4.
One Square Foot EDR is equivalent to net emission of 240 BTU per hour with 215°F steam in the radiator surrounded by 70°F air temperature.
*** Basic ratings for trap pressures greater than 25psi are given in lbs of condensate per hour.
One pound of condensate is equivalent to approximately 1000 BTU; 1000 BTU is equivalent to approximately 4 square feet EDR.