SDS
Page 2 of 7 
Puffy 3D Paint –S-17-0058 
5. FIRE FIGHTING MEASURES 
Extinguishing Media 
Suitable extinguishing media: 
Water. Foam. Dry powder. Carbon dioxide (CO
2.
) Use extinguishing media 
appropriate for surrounding fire. 
Unsuitable extinguishing media: 
None. 
Protection of Firefighters 
Specific hazards arising from the chemical: 
No particular hazards. 
Protective equipment for firefighters: 
Use standard firefighting procedures and consider the hazards of 
other involved materials. 
Special precautions for fire fighters: 
Wear full protective clothing, including helmet, self-contained 
positive pressure or pressure demand breathing apparatus, 
protective clothing and face mask. 
Will hazardous combustion occur?: 
Will not occur. 
6. ACCIDENTAL RELEASE MEASURES 
Personal Precautions: 
Extinguish all ignition sources. Avoid sparks, flames, heat, 
and smoking. Ventilate. Avoid inhalation of vapors and 
contact with skin and eyes. Wear suitable protective 
clothing. See Section 8 of the MSDS for Personal Protective 
Equipment. 
Environmental Precautions: 
Do not allow to enter drains, sewer or water course. 
Methods for Cleaning Up: 
Clean up in accordance with all applicable regulations. 
Remove sources of ignition. Absorb spillage with non-
combustible, absorbent material. Containers with collected 
spillage must be properly labeled with correct contents and 
hazard symbol. 
Recommended Personal Protective Equipment: 
See Section 8 of this SDS. 
7. HANDLING AND STORAGE 
Safe Storage: 
Store in a cool, dry place. Keep in container closed when not in use. 40 – 100°F. 
Protect from freezing. 
Safe Handling: 
Wash thoroughly after handling. Removing contaminated clothing and wash 
before reuse. Avoid contact with eyes. Avoid ingestion and inhalation. 
Known Incompatibilities: 
None known. 
8. EXPOSURE CONTROL AND PERSONAL PROTECTION 
Occupational Exposure Limits:  
Chemical name 
ACGIH 
OSHA PEL 
NIOSH IDLH 
Titanium Dioxide 
13463-67-7 
10 mg/m3 TWA; Appendix A4 - Not 
Classifiable as a Human Carcinogen 
15 mg/m3 TWA 
5,000 mg/m3 
Carbon Black 
1333-86-4 
3.5 mg/m3 TWA 
 (inhalable particulate matter) 
TWA 3.5 mg/m3 
TWA 3.5 mg/m3 Ca TWA 
0.1 mg 
Appropriate Engineering Controls: No special requirements under ordinary conditions of use and with adequate 
ventilation. 
Individual Protection measures, such as PPE (Personal Protective Equipment): 
Personal Protection Equipment: 
Respiratory Protection: 
None required under normal handling conditions. 
Eye Protection: 
Wear safety glasses with side shield. 