Datasheet
11/11 
Tufvassons Transformator AB  Märstavägen 20  193 40 Sigtuna  Phone +46 (0) 8 594 809 00 
Fax +46 (0) 8 592 527 68  E-mail reception@tufvassons.se  www.tufvassons.se 
A company in the ADDTECH group. 
For lower-energy lighting 
Tufvassons have a wide range of transformers and over fifty years’ experience of 
making them ourselves. We offer safe lighting transformers with low running costs, 
and help you to select the right one. If you need a product that is not available, we 
will ensure it is made.
Easy to install, easy to connect 
The transformer is suitable for all kinds of low-voltage 
lighting, for 12 V AC and optimum efficiency in the light 
source. The light source will last longest if the 
recommendation for minimum loading is followed. The 
transformer is easy to install (keyhole socket) and to 
connect. The connection glands are specially designed to 
fit tightly round the cable. And of course, the product also 
has short-circuit and overload protection, and complies 
with the insurance companies' requirement for self-
extinguishing plastic in the housing.  
Type: PVS 60
Part.no.: 6009-0030
Input voltage:  230V, 50-60 Hz; (N - L)
Output voltage:  11.5V
Lamp power:  max. 60 W (5 A), min. 35 W
Weight: 1.3 kg
Encapsulation class:  IP54
Insulation class: 4.2 kV
Ambient temperature:  max. 25 
o
C (at 35 
o
C, the transformer can supply a load of max. 50 W).
Design:  - Transformer potted in hard-setting plastic, with grey encapsulation made from impact resistant, 
self extinguishing thermoplastics.
  - Double insulated (earth connection not required). 
  - Built-in, replaceable secondary low-voltage fuse 5 AT (5x20 mm). 
  - Primary entry gland for cable diameter max. 13 mm, 2-pole 4 mm² terminal. 
  - Secondary entry gland for cable diameter max. 13 mm, 2-pole 4 mm² terminal. 
  - Max torque for the screw terminal is 0.5 Nm. 
Mounting:  Wall mounting with 2 screws. Upper hole is a keyhole slot.
Manufacturing standard:  Security:  EN 61 558-1; EN 61 558-2-6
  Emissions:  EN 61 000-6-3, IEC 62041 
  Immunity:  EN 61 000-6-2, IEC 62041 
Other information:  If demanded by the installation regulations, the transformer must be connected by an all-pole 
switch in permanent installations.