CONTROLS:
LOW FREQUENCY
SECTION:
The low frequency section consists of a
PEAK
control and a
LOW FREQUENCY
switch located to the left.
PEAK: The
PEAK
control is continuously variable from 0 dB to +10 dB.
It is of the bell type.
LOW
FREQUENCY: The
LOW FREQUENCY
switch determines at which
frequency the maximum peaking is obtained.
There is a choice of 5 frequencies:
0.2, 0.3, 0.5, 0.7 and 1 kHz.
MID FREQUENCY
SECTION:
The mid frequency section consists of a
DIP
control and a
MID FREQUENCY
switch located to the left.
DIP: The
DIP
-control is continuously variable from 0 dB to -10 dB.
It is of the bell type.
(050504)
MID
FREQUENCY: The
MID FREQUENCY
switch determines at which
frequency the maximum peaking is obtained.
There is a choice of 11 frequencies:
0.2, 0.3, 0.5, 0.7, 1, 1.5, 2, 3, 4, 5 and 7 kHz.
HIGH FREQUENCY
SECTION:
The high frequency section consists of a
PEAK
control and a
HIGH FREQUENCY
switch located to the left.
PEAK: The
PEAK
-control is continuously variable from 0 dB to +8 dB.
It is of the bell type.
HIGH
FREQUENCY: The
HIGH FREQUENCY
switch determines at which
frequency the maximum peaking is obtained.
There is a choice of 5 frequencies:
1.5, 2, 3, 4 and 5 kHz.
IN/OUT:
The in/out key switches the filter in and out of the signal path.
The amplifier remains in the circuit.
(040319)