A List of Built-In Self-Tests
Appendix A shows a complete list of Built-In Self-Tests.
ID Name C I PA P Type Reaction Confirmation Min Max Reconfigurable
002 VOLTAGE_SUPERVISOR ● BITVEC LOG 1 0 0 Yes
101 0V85_VOLTAGE ● VOLT LOG 3 765 mV 935 mV Yes
102 0V9_VOLTAGE ● VOLT LOG 3 810 mV 990 mV Yes
103 1V2_VOLTAGE ● VOLT LOG 3 1080 mV 1320 mV Yes
104 1V8_VOLTAGE ● VOLT LOG 3 1620 mV 1980 mV Yes
105 2V5_VOLTAGE ● VOLT LOG 3 2250 mV 2750 mV Yes
106 3V3_EXT_VOLTAGE ● VOLT LOG 3 2970 mV 3630 mV Yes
107 3V3_INT_VOLTAGE ● VOLT LOG 3 2970 mV 3630 mV Yes
003 125MHZ_25MHZ_CLCK_COMP ● BITVEC LOG 3 0 0 Yes
006 RLDRAM_DED_CHECK ● COUNT RESET_ENFORCED 1 0 0 Yes
110 RLDRAM_DED_CHECK_CHANGE ● COUNT LOG 1 0 0 Yes
007 RLDRAM_SEC_CHECK ● COUNT LOG 1 0 0 Yes
009 SWE_PORT ● BITVEC LOG 1 0 0 Yes
011 LOOPBACK ● BITVEC LOG 1 0 0 No
014 ASIC_DEV_ID ● ● ● BITVEC SHUTDOWN_ENFORCED 2 0x0032F001 0x0032F001 No
016 Test WD reset ● BITVEC safe mode 1 0 0 No
017 CPU_BOOT_SELF_TEST ● ● BITVEC safe mode 2 0 0 No
018 Watchdog ● N/A HW-triggered reset 1 0 0 Yes
021 FRAM_AVAILABILITY ● ● N/A safe mode 2 0 0 No
025 CRC_CHECK ● ● ● BITVEC LOG + explicit SHUT-
DOWN_ENFORCED
2 0 0 Yes
026 CRC_ASIC_CP ● BITVEC RESET_ENFORCED 1 0 0 Yes
030 ASIC_CONFIG_CRC ● ● ● BITVEC LOG + explicit SHUT-
DOWN_ENFORCED
2 0 0 Yes
032 SMC2_TEMPERATURE ● TEMP LOG 3 -53 °C 122 °C Yes
045 ADC_VERIFY ● BITVEC LOG 2 0 0 No
047 RLDRAM_DED_VERIFY ● BITVEC SHUTDOWN_ENFORCED 2 4 4 No
048 RLDRAM_SEC_VERIFY ● BITVEC SHUTDOWN_ENFORCED 2 2 2 No
050 ASIC_REJECT_CFG ● BITVEC SHUTDOWN_ENFORCED 2 5 5 No
051 Power Supply Voltage Monitor ● N/A HW-triggered reset 1 0 0 Yes
053 RESET_CMD ● BITVEC safe mode 1 0 0 No
054 COMPARE_TEMPERATURE ● TEMP LOG 3 0 °C 29 °C Yes
056 ASIC_POS_ID ● ● ● BITVEC LOG + explicit SHUT-
DOWN_ENFORCED
2 0 0 Yes