3. FUNCTIONAL DESCRIPTION
• Voltage: 85 VAC - 264 VAC
• Frequency: 47 Hz - 63 Hz
Power Consumption:
The switch consumes a maximum of 45 W.
Grounding:
• For ESD protection, Signal Ground (GND) is connected with 5 x 1 nF and 2 x 10 MΩ to CHASSISGND.
• Signal Ground (GND) is AC/DC-coupled with CHASSISGND, which is connected to the housing and
the metal-plated connectors (Ethernet RJ45, SFP Cages, D-SUB DE-9, D-SUB DE-25), which can
be accessed from outside.
© TTTech Computertechnik AG 2020. All rights reserved.
Confidential and Proprietary Information
17
Document Number:
D-A664Lab-G-05-001