Operation Manual

Instruction
Form:DP5-005 Revised:05 36
Process for BodyNo write, Diag inspection, BodyNo delete
* is set when it is delivered.
< TM4875B /TM5317B specifications>
In the United States and Canada, use of 2480 MHz is restricted to correspond to FCC / IC.
If 2480 MHz is set, the wireless module automatically changes to 2479 MHz.
In other countries, there is no use restrictions on frequency.
Wireless VIM station setting Purpose explanation
Initial mode Wireless frequency 2453MHz(Ch52) Same frequency as
wireless VIM is required.
Wireless ID 52
Inspection mode Wireless frequency 2456MHz (Ch55) Frequency settings for
process
Wireless ID 0 Same ID as parameter write
waiting mode is required.
Parameter writing
waiting mode
Wireless frequency 2480MHz(Ch79) Same frequency as
wireless VIM is required.
Wireless ID 0
Parameter writing
mode
Wireless frequency 2456MHz(Ch55) Frequency settings for
process
Wireless ID 55