6. SPECIFICATION OF INPUTS AND OUTPUTS
6.5.2 Functional description
t.b.d.
6.5.3 Maximum ratings
Symbol Parameter Min Max Unit
V
in max
Permanent (DC) input voltage -1 33 V
6.5.4 Characteristics
Symbol Parameter Min Max Unit
C
in
Pin input capacitance 8 12 nF
V
IL
Input voltage for low level -1 2 V
V
IH
Input voltage for high level 3 32 V
6.6 100BASE-TX interface
Supported by the Vision 312Plus products.
6.6.1 Pinout
Connector Pin no./Shield Function
A 1 Ethernet TX+
A 2 Ethernet RX-
A 3 Ethernet TX-
A 4 Ethernet RX+
A Shield Ethernet SHIELD
6.6.2 Functional description
The 10/100 Mbit full-duplex Ethernet port is compliant with IEEE 802.3.
Use cabling that is compliant with the Ethernet standard; at least Ethernet CAT5 cable for 100 Mbit/s, and
Ethernet CAT3 cable for 10 Mbit/s transmission speed. In a noisy environment it is recommended to use
shielded cables. In this case, the connector’s shield must be connected to the shield of the Ethernet cable.
6.6.3 Maximum ratings
Symbol Parameter Min Max Unit
V
in-CMM
Input common mode range DC or AC-peak with line frequency
(max 60 Hz)
200 V