Brochure

1514
TSUNAMI PRODUCT CATALOG 14
1.800.782.5752
|
TSUNAMI.US.COM
15
MOISTURE MINDER
®
FILTER DRAIN
Neglecting to consistently drain condensate and contamination will result in
endless headaches and costly downtime. Inadequate or forgotten draining
dramatically wears on filtration systems causing them to become ineffective
and damaging to critical equipment and processes. Tsunami offers a variety
of drain styles to assure timely and efffective draining for your facility.
MOISTURE MINDER
®
PNEUMATIC DRAIN
Available in both external
reservoir or internal
reservoir models.
MOISTURE MINDER
®
FILTER DRAIN
Designed to spin on the
corresponding size Tsunami
filter tube.
PART
NUMBER
MAX
PSI
PORT
SIZE
WEIGHT DIMS (HWD)
142-0000 250 ¼” NPT 2 lbs 1½” x 6½” x 1½”
152-0000 250 ¼” NPT 2 lbs 5” x 5½” x 2”
21999-0317 Pneumatic Drain Installation Kit
PART
NUMBER
FILTER
SIZE
MAX
PSI
WEIGHT DIMS (HWD)
21999-0792 20 CFM 250 1 lbs 4” x 3” x 2”
21999-0795 50 CFM 250 1 lbs 4” x 3½” x 3½”
21999-0805 120/240 CFM 250 1½ lbs 4” x 3½” x 3”
MOISTURE MINDER
®
ELECTRONIC DRAIN VALVE
ITEM # POWER DUAL SIZE INLET WEIGHT DIMENSIONS
21999-0177 115v AC / 60Hz ¼” ID & ½” OD 1 lb 5½” x 3½” x 3½”
21999-0177-230 220v AC / 60Hz ¼” ID & ½” OD 1 lb 5½” x 3½” x 3½”
21999-0177-230-50 230v AC / 50Hz ¼” ID & ½” OD 1 lb 5½” x 3½” x 3½”
21999-0177-24 24v DC ¼” ID & ½” OD 1 lb 5½” x 3½” x 3½”
21999-0177-12 12v DC ¼” ID & ½” OD 1 lb 5½” x 3½” x 3½”
21999-0316 Electronic Drain Installation Kit
MOISTURE MINDER
®
ELECTRONIC DRAIN VALVE (EDV)
1
2
3
4
The Moisture Minder
®
EDV incorporates a self-cleaning feature where a fixed strainer
screen is used to capture contaminates before reaching the valve orifice. Opening the
manual ball valve automatically flushes the strainer screen clean. The drain is compatible
with various types of media and conforms to the NEMA 4 standard.
Adjustable Timer: OFF: 0.5 - 45 minutes ON: 0.5 - 10 seconds
Internal screen and ball valve allows for self cleaning
Dual Size Inlet: Accommodates 1/4” I.D. or 1/2” OD NPT thread sizes
1/4 turn ball valve allows for self cleaning without disassembling
1
3
2
4
FLOAT DRAIN
REPLACEMENT
Includes 3 float drains and o-rings for
replacement in Tsunami filters.
DRAIN MINDER II
CONTROLLER
Provides the pilot signal every 30 seconds to
120 minutes to multiple pneumatic drains.
HOW IT WORKS
DRAIN MINDER II AUTOMATIC TIMER
The Drain Minder II can deliver the pilot signal needed to operate
the Moisture Minder pneumatic drain valves when no other
intermittent pilot signal is available. The control is installed in the
typical system by teeing into a filtered air supply and connecting
the supply line to the inlet side of the controller solenoid.
PART NUMBER DESCRIPTION
144-0001 Drain Minder II Controller
PART NUMBER DESCRIPTION
21999-0868 Float Drain 3-Pack
PILOT SIGNAL RECEIVED
Condensation enters left hand, or
water inlet of valve.
1
PILOT SIGNAL FROM UNLOADER
Piston shifts, closing off drain port. As
piston moves, it will open up the stainless
ball check allowing condensate to be forced
into pressurized discharge reservoir.
2
VALVE AT REST
When pilot signal is relieved, piston returns to
relaxed position. The ball check closes preventing
zero pressure loss in the system. The drain port
opens and the stored condensate is ejected.
3
TIMER ACTUATES
Condensation enters through
the inlet side of valve. Debris is
captured inside the internal strainer.
DEBRIS IS EJECTED
When valve activates condensate flows thru
strainer up to the orifice and out the back
discharge port. Debris is captured by internal
strainer which prevents fouling.
SELF CLEANING
Only open ¼” ball valve to clean
strainer or to manually drain the tank.
2
1 2 3
ELECTRONIC DRAINS
AUTOMATIC DRAINS
MOISTURE MINDER
®
1
MOISTURE MINDER
®
2
HOW IT WORKS
PNEUMATIC PISTON DRAINS
HOW IT WORKS