HOW IT WORKS
TSUNAMI REGENERATIVE DRYER REFRIGERANT DRYER
The Drying Process
Can handle high inlet temperature up to 150°F
Performs well with high demand surge flows
No Aftercooler Required
Complete with 2-stage pre-filters
& automatic drains
Dew points … down to –80°F and lower
No refrigerant to maintain
Works great with low flow rates
Minimal maintenance required:
-
Change oil coalescing element every six months
Max inlet temperature 100°F
Moisture will carry over during high demand surge flows
Requires Aftercooler
Must purchase pre-filters and automatic drains separately
Dew points … 35-50°F
Refrigerant to maintain
Low flow rates may allow water carry over at separator
Regular maintenance required:
-
Clean heat exchanger | Electric motor
Refrigerant compressor
HOW DO WE STACK UP?
1
2
3
Pre-filtered air enters the dryer and
is channeled through the desiccant
tower(s).
Wet air passes through the tower(s)
where molecular sieve desiccant
draws water vapor in while under
pressure.
After flowing through the desiccant,
the now dry air is sent downstream.
After two minutes, the control timer
sends out a pilot signal shifing the
internal piston. When the piston
shifts, air is redirected from this
tower(s) to the opposite side.
1
2
3
4
4
Tsunami Regenerative Drying Systems use proprietary
technology to provide extremely clean and dry air.
Low relative humidity - down to .01% RH
Dew points down to -80°F
Easy, low-cost maintenance - under $1000/year average
Includes Tsunami Water Separator and Oil Coalescing Filter with automatic drains
AIR DRYERS
The Regeneration Process
A small amount of air from the dry
outlet on the opposite tower(s)
percolates up through the regeneration
orifice and back through the desiccant
filled tower(s).
The desiccant is dried as the sweep air
passes back through the media.
With the use of this air, the tower(s)
discharge water vapor through the
dryers mufflers.
After two minutes, the control timer
sends out a pilot signal shifing the
internal piston. When the piston shifts,
flow is reversed and this tower(s)
begins drying the air.
VS
Ultra series wall-mounted regenerative dryers are designed as complete packages. Systems can be
configured in multiple variations allowing for pre-filtration to be installed on the left or right side of
the unit. Dual inlet/outlet ports allow for bypass of the dryer where breathing air is required.
ULTRA SERIES REGENERATIVE DRYERS INCLUDE:
Tsunami rail mounted regenerative dryers are built to withstand the largest surges of contamination.
Similar to other Tsunami drying systems, these dual-inlet units are built as complete packages.
The optimal solution for any facility; simply connect shop air into the inlet fitting and out the regulator. It’s
that simple. Tank-mounted come fully assembled to provide for absolute ease of installation. A built-in
bypass system allows the dryer to be shutoff for maintenance or service without stopping production.
ULTRA REGENERATIVE DRYERS
WALL-MOUNTED DRYERS
TANK-MOUNTED DRYERS
ITEM # SIZE MAX CFM DRAIN PORT SIZE WEIGHT DIMENSIONS
21999-0810 10 HP 40 Pneumatic 1” NPT 335 lbs 5¾" x 4¼" x 2¼"
21999-0815 15 HP 60 Pneumatic 1” NPT 358 lbs 5¾ x 4¼” x 2¼”
21999-0820 20 HP 80 Pneumatic 1” NPT 381 lbs 5¾ x 4¼” x 2¼”
21999-0830 30 HP 120 Pneumatic 1” NPT 381 lbs 5¾ x 4¼” x 2¼”
RAIL-MOUNTED DRYERS
ITEM # SIZE MAX CFM DRAIN PORT SIZE WEIGHT DIMENSIONS
21999-0750 50 HP 200 Pneumatic 1” NPT 267 lbs 5½" x 3" x 1¾"
75 HP, 100 HP, 125 HP, and 150 HP available on request. Call for details.
ULTRA SERIES WALL-MOUNTED
ULTRA SERIES RAIL-MOUNTED
ULTRA SERIES TANK-MOUNTED
2-stage Pre-fitration; Water Separator, Oil Coalescing Filter
Regenerative Dryer
Moisture Minder
®
Automatic Drains
Programmable Logic Control (PLC).
21999-0710
21999-0750
21999-0810
In addition to our complete line of standard products, Tsunami has engineered customizable
dryers to meet air cleanliness requirements for a variety of industries and applications. Call
1.800.782.5752 to learn more.
ITEM # SIZE MAX CFM DRAIN PORT SIZE WEIGHT DIMENSIONS
21999-0710 10 HP 40 Pneumatic 1” NPT 73 lbs 2½" x 2½" x 1"
21999-0715 15 HP 60 Pneumatic 1” NPT 93 lbs 2½” x 3” x 1”
21999-0720 20 HP 80 Pneumatic 1” NPT 118 lbs 2½" x 3½" x 1"
21999-0730 30 HP 120 Pneumatic 1” NPT 118 lbs 2½” x 3½” x 1”
3-Year Warranty on
Tsunami Ultra Drying Systems
Dryer flow rates based on 100°F at 175 PSI with an outlet pressure of 100 PSI.*
Lower inlet pressure and higher temperatures affect the performance and quality of the downstream air.
*minimum inlet pressure 80 PSI
Parts sent globally will include a -G with the part number.