Product Guide
7
LOW MAINTENANCE
• Only second-stage oil coalescing
element needs replacing
• No refrigerant to maintain
• No desiccants to replace
• No desiccant dust downstream
EASY TO INSTALL
• No electrical connection
• Mount outside paint booth
• Comes pre-assembled
Membrane Drying System
INLET
PRESSURE
INLET
TEMPERATURE
PRESSURE
DEW POINT
30 PSI
40 PSI 50 PSI
175 80° 17° (9) -10° (2) -7° (2) -5°(3)
150 80° 22° (11) -3° (3) -1° (4) 3°(4)
100 80° 40° (24) 19° (9) 23° (11) 27°(14)
(RH%)
DEW POINT @ SPRAY GUN PRESSURE SETTING
• First-stage Tsunami Water Separator with Automatic Float Drain
• Second-stage Tsunami Oil Coalescing Filter with Automatic Float Drain
• Membrane Dryer Unit
• High Flow Piston Regulator
**REMINDER**
Always replace your hose when
installing new spray booth filtration
Tsunami Ultra-flo Spray Hose
P/N 21999-0496 15’
P/N 21999-0449 35’
P/N 21999-0450 50’
SPECIFICATIONS
• 20 CFM max inlet flow w/ 16.7 CFM max outlet flow
• 3.3 CFM sweep air @ 100PSI
• 175psi maximum inlet pressure
• 60psi maximum outlet pressure
• 100° F maximum inlet air temperature
• ½” NPT ports
P/N 21999-0357
Height - 23” Width - 16” Depth - 5”
Inlet - ½” NPT Outlet - ½” NPT
Single Tower Regenerative Dryer
P/N 21999-0722
Includes:
• 3-year warranty
• Economical solution for single booth
application while still providing high
quality dry air
• Tsunami water separator and oil
coalescing filter to pre-
treat the
incoming air
• Outlet regulator allows for better
pressure control and conserves air
• Easy to install
• Manual control valve can be mounted
50 feet from dryer