SDS
LN-950 POLYURETHANE AHE95012TN0
Product name
5
Product code
Date of issue
Version
00407720
17 August 2015
Section 4. First aid measures
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. If it is
suspected that fumes are still present, the rescuer should wear an appropriate mask or
self-contained breathing apparatus. It may be dangerous to the person providing aid to
give mouth-to-mouth resuscitation. Wash contaminated clothing thoroughly with water
before removing it, or wear gloves.
Notes to physician
:
In case of inhalation of decomposition products in a fire, symptoms may be delayed.
The exposed person may need to be kept under medical surveillance for 48 hours.
Specific treatments
:
No specific treatment.
Skin contact
Ingestion
No specific data.
Adverse symptoms may include the following:
irritation
redness
dryness
cracking
:
:
See toxicological information (Section 11)
Indication of immediate medical attention and special treatment needed, if necessary
Section 5. Fire-fighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
Hazardous thermal
decomposition products
Specific hazards arising
from the chemical
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
nitrogen oxides
metal oxide/oxides
Flammable liquid and vapor. In a fire or if heated, a pressure increase will occur and
the container may burst, with the risk of a subsequent explosion. Vapors may
accumulate in low or confined areas or travel a considerable distance to a source of
ignition and flash back. Runoff to sewer may create fire or explosion hazard.
Fire-fighters should wear appropriate protective equipment and self-contained breathing
apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Special protective
equipment for fire-fighters
Use dry chemical,
CO₂,
water spray (fog) or foam.
Extinguishing media
:
:
:
Do not use water jet.
Suitable extinguishing
media
:
Unsuitable extinguishing
media
:
Special protective actions
for fire-fighters
:
United States