Model: LED200WFB Installation & Operating Instructions 2x 10W LED Wi-Fi PIR Twin Floodlight - Black
1. General Information These instructions should be read carefully and retained for further reference and maintenance. Note: Timeguard reserve the right to alter these instructions at any time. Up to date instructions will always be available for download at www.timeguard.com 2. Safety • Before installation or maintenance, ensure the mains supply to the luminaire is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• Motion Detection Range: Up to 10m at a 2.5m mounting height • Detection Angle: 140˚ • Full Light Time On Adjustment: 5 seconds to 60 minutes • 2nd Stage Time On Adjustment: 1 minute to 8 hours • Lux Adjustment: 10 to 1000 lux • Standby Power Consumption: 0.
5. Tuya Smart App Requirements • Smartphone/Tablet with at least iOS 11.0 or Android 7.0. Minimum requirements subject to Tuya Inc. and not Timeguard. • WLAN-enabled router: 2.4GHz (Separate Band) 6. Selecting a location 3 • The PIR has a number A of detection zones, at various vertical and horizontal angles as shown. See image A • The best all-round coverage is achieved with the floodlight mounted at the optimum height of 2.5 metres. See image B.
7a. Installation 4 This section covers installation without the use of the corner bracket. If the corner bracket is required for installation refer to section 7b Installation (Corner Bracket). 1 • Mark the position of the mounting holes on the wall using the back box as a template (See image 1). Drill the holes ensuring not to infringe with any gas/water pipes or electrical cables that may be hidden below the surface. • Insert the rawl plugs into the holes.
7b. Installation (Corner Bracket) 5 • Mark the position of the mounting holes on the wall using the corner bracket as a template (See image 3). Drill the holes ensuring not to infringe with any 3 gas/water pipes or electrical cables that may be hidden below the surface. Knockout • Insert the rawl plugs into the holes. If mounted to an external corner, as shown, there is a thin web of plastic that needs to be removed with cutters before installation.
8. Connection Diagram N L 230V AC 50Hz MAINS SUPPLY N L E ISOLATION SWITCH E 6 Note terminal E is for earth continuity only. 230V 50Hz Mains Supply Live Supply (Brown or Red) Neutral Supply (Blue or Black) to Earth (Green/Yellow) to L N E • After the mains supply cable has been terminated. Re-connect the luminaire to the back box ensuring that the two lugs firmly latch on the left and right hand side, indicated by a ‘click’.
9. Downloading App & Registration Note: the mobile or tablet device must be connected to a 2.4GHz band on the router. Pairing on the 5GHz band will result in pairing timing out or being unsuccessful. Refer to your ISP (Internet Service Provider) on separating the bands if required. • Ensure your phone or tablet is connected to your local Wi-Fi network. • Download the Tuya Smart App onto your phone or tablet by searching for ’Tuya Smart’ on Google Play or the App Store.
• Assign a password (this must be between 6 to 20 characters including letters and digits) and click ‘Done’. The App home page will now appear. 10. Pairing Your Device(s) Note: if you are using a VPN, make sure this is disabled before continuing, and ensure that the 2.4GHz Wi-Fi band is enabled for this device, separate from the 5GHz band. • Once you are on the home page of the Tuya Smart App press the plus button ‘ ’ on the top right hand side of the app.
12. Controls Screen 1 Temperature Wheel: Sets the colour temperature of the luminaire. Left: Warm White Right: Cool White 2 1 Manual Override: Switch ON/OFF the luminaire as required. Note this is a permanent state. 2 3 Delay Setting: Delay either the startup or shutdown times of the luminaire. Note this function reverses the current state of the luminaire after a certain amount of time. 4 3 4 Schedule: Setup timed ON/OFF parameters for the luminaire to switch on/off during a 7 day period.
1 Full Light Duration: Set the timeout duration of the luminaire after being triggered via the PIR. 1 2 2 Hi-Lo Dimming (2nd Stage Lighting): Enable the light to stay on at a dimmed level once the PIR detects there is no movement in the detection area. 3 3 4 Hi-Lo Dimming (2nd Stage Brightness): Set the brightness of the luminiare once the full light duration peroid has ended.
If you experience problems, do not immediately return the unit to the store. Email the Timeguard Customer Helpline: HELPLINE helpline@timeguard.com or call the helpdesk on 020 8450 0515 Qualified Customer Support Coordinators will be online to assist in resolving your query. For a product brouchure please contact: 67.058.705 (Issue 1) T.W - December 2022 Timeguard Limited. Victory Park 400 Edgware Road, London NW2 6ND Sales Office: 02084521112 or email csc@timeguard.com www.timeguard.