Product Description
2.Panels
2.2.Rear panel of the UWB Gateway
The rear panel of U3000-t UWB Gateway includes network connector, power
supply connector, reset button and label.
3.Installation and power supply
3.1.Installation of UWB Gateway
The U3000-t UWB Gateway is generally installed near the entrance, and the
installation height is generally 2m. The installation method is as follows:
UWB gateway can only effectively cover a distance of 3~5m. It should be installed
with care to function normally. You need to pay attention to the following:
The UWB Gateway should be installed in the correct posture, face down.
The UWB Gateway should not be installed vertically or at an angle.
The UWB Gateway should not be blocked by objects. Keep away from
obstructions such as weak current bridges, fire pipes, air conditioning pipes and
other shelters.
Avoid installing the UWB Gateway on top of the ceiling (no matter the material
of the ceiling is metallic,like aluminum gussets, or non-metallic, like gypsum
boards and glass plates).
Keep away from objects that easily cause signal reflection, including large-area
metals and large screens.
Description
1 RJ45 Network Port
PoE power input & network transmission
multiplexing port.
When power is on, use a needle to press
this button and hold for 15 seconds and
then release. The UWB Gateway will
restore the factory settings and restart.
DC power input interface, connect
to 24VDC/1A adapter.
UWB Gateway information.
Reset Button
DC24V Power
Adaptor Port
Label Zone
2
3
4
Ceiling installation Suspension installation
CEILING CEILING
43