OPERATION, INSTALLATION AND MAINTENANCE MANUAL THX Flush Mount Enclosure Ta k e h e a t i n g t o t h e Ma x !
Mounting options March 2023 Rev 2 The installation of HEATSTRIP® Max is simple and easy with the standard mounting brackets supplied. For other more challenging locations there are range of mounting options available - refer to below diagrams. The HEATSTRIP® Max can be mounted directly to the ceiling, angled downwards on a wall, fitted flush with the ceiling; suspended on chains or poles; attached to beams or poles; mounted end-to-end, or 2 units together.
Flush Mount Enclosure The Flush Mount Enclosure is an ideal way to neatly install the HEATSTRIP® Max into a ceiling. They are available for both HEATSTRIP® Max models, and are supplied as a one-piece unit for mounting of heaters. Flush mounting can be used with plaster or wood lined ceiling materials. An ideal mounting height is 2.4m-3.0m, with a maximum ceiling height of 3.5m in an outdoor environment.
Flush Mount Enclosure dimensions View from top View from underneath 4 PART No MODEL “A” (mm) “B” (mm) “C” (mm) THHAC-030 THX2400 995 940 935 THHAC-031 THX3600 1320 1265 1260
Installation Clearance Dimensions Shown in the diagrams below are the minimum clearance required for the installation of the Flush Mount Enclosure. It is imperative that all cables, backing materials, insulation and other materials are keep clear of the back and the sides of the Flush Mount Enclosure.
Installation Instructions Ensure all minimum clearance requirements are met and the materials used are compliant to your local building codes. Before installing the flush mount enclosure, ensure the site to be fixed is fully prepared with the hole cut the correct size and the mounting points securely in place. STEP 1: Attach the brackets to the rear of the heater. The dimensions for the spacing of the brackets is listed in the table. STEP 2: Screw the enclosure into the battens.
Safety In operation, this heater is VERY HOT— do not touch any part of the heater while it is turned on. Do not touch any part until 30 minutes after it is turned off. This appliance is not intended for use by persons (including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Warranty Terms & Conditions The below Warranty Terms and Conditions apply for New Zealand and Australia only. For international warranty please refer to international warranty terms and conditions. Thermofilm warrants to the original owner that the FLUSH MOUNT ENCLOSURE product will be free from defects in materials and workmanship for a period of 12 months from the date of purchase in accordance with the following warranty terms and conditions.