User Manual
Calibration
Calibration adjustment is permanent and
should only be performed using accurate
calibration weights that match the
requirements for your scale (see the chart on
back). Do not use coins or other household
items to calibrate.
1. Prepare the required weight for your scale. (see
chart on back)
2. Find a at and level surface to perform calibration
and let the scale adjust to room temperature.
3. Press ON/OFF to turn the scale on and wait for the
scale to stabilize.
4. Press and hold the MODE/CAL key until the display
shows ‘CAL’.
5. Make sure nothing is on the platform then press
MODE/CAL to conrm the zero point.
6. The display will then ash the required calibration
weight.
7. Place the required
calibration weight on the
center of the platform.
8. The display will show
‘PASS’ then return to
normal weighing mode.
You may now turn the
scale o or continue
weighing.
Radio Frequency
Interference
Unlevel Surfaces High Humidity
Air Currents Vibration Extreme Temps