Truma UltraRapid LPG and 230 V / 240 V Electric Storage Water Heater Installation instructions
Truma UltraRapid Fig. 1 Table of contents Symbols used ...................................................................... Model .................................................................................... Technical data ..................................................................... Data label ............................................................................... Intended use .......................................................................... Regulations .................
Technical data Installation instructions Protection type / protection class IP21 / class I Water capacity 14 litres Rated water pressure 400 kPa Maximum working water pressure / temperature P&T relief valve setting 500 kPa – 99 °C – 10 kW Type of gas Universal LPG Test point pressure 2.75 kPa Nominal heat input 5.2 MJ/h (HS) Nominal heat output 1.2 kW Gas consumption 5.2 MJ/h Injector size 0.70 mm Heating up time from approx. 20 °C up to approx. 65 °C (14 litres) Gas operation: approx. 45 min.
Water heater kit Installation dimensions The water heater kit contains: Additionally required: 1 Cowl assembly with screws 5 40 Fig.
If there are any cavities in the area of the cowl, pack these with pieces of wood so as to be able to tighten the screws. 9b 9a Fig. 7 Cut out trim strips or such on the vehicle or place supports beneath them so as to make the cowl lie flat. Place a support beneath the heater if the walls are sloping. An angle of inclination of 10 degrees is not to be exceeded. Insert heater with cowl body (Fig. 8-1) through the wall cutout (Fig. 8-2), allow approx. 5 mm to project out of the wall.
The supplied water connectors (Fig. 11.-12 + -13) and the drain valve (Fig. 11.-14) have a 12 mm rigid piping connection (e. g. John Guest System). For connecting to rigid pipes with other diameters appropiate adapters (not included in scope of delivery) must be used. The draining is to be directly to the outside at a position protected against splash water (apply splash guard, if necessary).
gas leaks and check the gas pressure). Do not check for gas leaks with a naked flame. 21 12 Ø 12 mm 20 13 20 mm 45º Installation of the control panel gas When using control panels which are specific to the vehicle or the manufacturer, the electrical connection must be established in accordance with the Truma interface descriptions (refer to Electrical connection 230 V / 240 V ). Any modification made to the Truma components pertaining to this will void the warranty and exclude any liability claims.
The 12 V electrical connection is made at the clamp (Fig. 19-35). orange = positive 12 V blue = negative This is done by pressing from above with a small screwdriver and pushing the cable in from the front. Connect to the fuse-protected on-board power supply (central electrical system 5 – 10 A) using a 2 x 1.5 mm² cable. Connect negative line to main ground connection. For lengths of over 6 m, use a 2 x 2.5 mm² cable.
Truma UltraRapid spare parts Gas Control Panel 230 V AC / 240 V AC When ordering spare parts, please always state the serial number and year of manufacture.
WH Ignition Coil 1 2 3 4 1 2 3 4 5 6 J3 J2 12 11 10 9 8 7 J1 6 5 4 3 2 1 Internal Fuse (1.
In Australia, always notify the Service Australia if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). Leisure-Tec Australia Pty. Ltd. 50 Metrolink Circuit, Campbellfield, VIC 3061 Australia Service Australia Telephone: +61 1300 07 2018 E-Mail: service@leisure-tec.com.au 70020-00375 · 00 · 11/2021 · © Having the equipment model and the serial number ready (see type plate) will speed up processing.