Truma UltraRapid LPG and 230 V / 240 V Electric Storage Water Heater Operating instructions To be kept in the vehicle! Page 4
Truma UltraRapid Fig. 1 Installation example Table of contents 1 2 3 4 5 Symbols used ...................................................................... 2 Model .................................................................................... 2 General safety notes ..........................................................
General safety notes The use of upright gas cylinders from which gas is taken in the gas phase is mandatory for the operation of gas regulators, gas equipment and gas systems. Gas cylinders from which gas is taken in the liquid phase (e. g. for fork lifts) must not be used, since they would result in damage to the gas system.
Pressure and Temperature Relief Valve (P&T safety valve) Operating instructions Always observe the operating instructions prior to starting! The vehicle owner is responsible for correct operation of the appliance. Risk of scalding injury from hot water and/or tampering with the P&T safety valve! –– Do not actuate the P&T safety valve as long as the appliance is still hot. –– Do not place a plug or reducing coupling in the discharge pipe (Fig. 2a - 4b) of the P&T safety valve.
Electrical operation 230 V – option – Switching on gas operation UltraRapid 230 V 60° a 70° / 240 V / 240 V 1300 W / 1415 W (5.7 A / 5.9 A) The Truma UltraRapid must not be operated with a time switch. b c b Never operate the Truma UltraRapid without water in it! Fig. 3 – To operate the electric heating element, insert the plug into the socket and then turn it on with the switch.
Technical data Check the power supply (operation voltage min. 10.5 V). Check the Truma UltraRapid fuse (refer to maintenance “Fuses”). –– Cowl cover fitted. –– Air in the gas supply. –– No gas supply. –– Incorrect gas pressure. Remove cowl cover and / or clear any obstruction. Check gas valves and gas cylinder. To unlock (and purge air), switch off the appliance, wait 5 minutes, and switch on again. Heater operates for a prolonged time and then the red lamp lights up.
Truma warranty policy The warranty is given by Service Australia for 24 months from the date of purchase against any defect arising from faulty materials or workmanship. Repairs will be carried out during normal business hours only by Service Australia, or its duly authorised service agents, and are subject to the warranty conditions and exclusions hereunder.
In Australia, always notify the Service Australia if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). 70020-00278 · 00 · 06//2018 · © Having the equipment model and the serial number ready (see type plate) will speed up processing.