Install Instructions
3
Technical data
Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir comfort RC AU, comfort air conditioning system
Number of structural units
1
Dimensions L x W x H
628 x 400 x 290 mm
Weight
approx. 23.5 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling power
2.4 kW
Heating power
1.7 kW
Effective power consumption
0.98 kW
Starting current
20 A (150 ms)
Power consumption
4.2 A / 35 °C
Protection class
IP X5
Energy Efficiency Rate (EER)
2.4
Volume flow (cold air)
max. 380 m³/h
Refrigerant
R 407C
Refrigerant content
see type plate on unit
Compressor oil
Diamond MA32, 300 cm³
Noise
depending on installation situation
Maximum incline of vehicle during operation
5° / 8 %
Usage limits
+4 °C to +43 °C.
– An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C during cooling.
– An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
– A temperature switch prevents excessive current and tem-
perature at the compressor.
Right reserved to make technical changes!
Only competent and trained staff (experts) are permitted
to install and repair the Truma product and to carry out the
function test, at the same time observing the installation
and operating instructions and the currently recognised
technical regulations. Experts are persons who, based on
their specialist instruction and training, their knowledge and
experience with Truma products and the relevant standards,
can carry out the necessary work properly and identify
potential hazards.
Scope of delivery
– 1 Saphir comfort RC AU
– 1 Remote control with batteries
– 1 IR receiver
– 4 Fastening brackets with screws, 1 clamping strap
– 2 Condensation traps
– 2 Floor grilles
– 1 Installation template
– 1 set of operating instructions / installation instructions
Intended use
This device has been designed for installation in motor homes
and caravans and is intended for use in the private sector.
Regulations
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
– Modifications to the device (including accessories)
– Failure to use original Truma parts as replacement parts and
accessories
– Failure to follow the installation and operating instructions
Selecting a location
Installation dimensions
The dimensions are in mm.
Ø 50
KO
Saphir comfort RC
LA
HW
HW
LE
620
186
301
400
197.5
74
96
213.5
81
15
122
28
10
Ø 50
KO
488
Fig. 3
Installation instructions