Aventa Product Manual

8
The clearance around the air distributor must allow the air to
blow out without obstructions. The side clearance must be at
least 40 mm. The pivoting range of flaps and doors must be
taken into consideration.
400
670
380
78
523
400
350
40
40
46
Fig. 9
Air inlets / outlets
Fig. 10
Condensation traps
The condensation is led away via the roof of the vehicle.
Fig. 11
Right reserved to make technical changes!
Installation dimensions (in mm)
670
1008
248
46
- 110
Fig. 6
400
(380)
400
(350)
523
195
(215)
530
660
Fig. 7
Clearance around the air conditioning system
The clearance around the external unit must be 20 mm at
the front and 100 mm at the side. At least 30 mm of clearance
must be left at the rear. Truma recommends clearance of
200mm so that the exhaust air can blow out freely.
10 0
660
10 0
100 8
200
20
30
Fig. 8