Troubleshooting
Fault Cause / Remedy
Appliance not cooling – Thawing procedure in progress
– Remote control temperature
setting reached or too high
Appliance providing in-
sufficient cooling or no
cooling at all
– Filter / panels dirty, replace
filter/clean panels
– External air routes soiled /
blocked
Moisture on underside
of air distributor
– Close windows and doors and
select high fan level
Water dripping out of
air distributor
– Condensation trap on external
unit blocked
– Seal between appliance and
roof not intact
– System at too much of an angle
Remote control
not working
– Check batteries in remote con-
trol and replace if necessary
Appliance not react-
ing to remote control
commands
– Check whether there are ob-
structions between the remote
control and the IR receiver
– Is the remote control tuned to
the IR receiver / Tune remote
control to IR receiver.
Compressor switches
off and back on again
after approx. 3 minutes
– Voltage drop at 230V
power
supply / check 230V
power
supply
If these actions do not remedy the problem, please con-
tact Service Australia.
Accessories
Aventa air filter kit, 2 pcs
for air distributor, not for air distributor small
(Part. No. 40091-16800)