Aventa compact plus AU Operating instructions To be kept in the vehicle
Aventa compact plus AU Symbols used Contents Symbols used ......................................................................... 2 Safety instructions .............................................................. 2 Notes on using air conditioning systems ........................ 3 Symbol indicates a possible hazard. Operating instructions Remote control ....................................................................... Start-up ....................................................................
Guarantee claims, warranty claims and acceptance of liability will be ruled out in the event of the following: ––changes to the device (including accessories), ––failure to use original Truma parts as replacement parts and accessories, ––failure to follow the installation and operating instructions. Such changes or non-compliance also invalidate the device operating permit, which in many countries also denotes expiry of the vehicle operating permit.
Operating instructions Remote control The symbols in the display are visible depending on the settings.
Start-up Sleep function Before switching on, be sure to check that the camp site has adequate power supply fusing (230 V). In “Sleep function” the internal and external fans operate at slow speed and are therefore extremely quiet. In order to prevent the power cable of the recreational vehicle from overheating (minimum cross-section 3 x 2.5 mm²) the cable drum must be fully unwound.
IR receiver and manual on / off IR remote control battery change There is an additional pushbutton on the IR receiver (m), with which the unit can also be switched on and off without the remote control (e.g. with a ballpoint pen). Only use micro-batteries that will not leak, type LR 3, AM4, AAA, MN 2400 (1.5 V). If the unit is switched on using this pushbutton, the system is automatically reset to the factory settings (automatic mode, 22 °C).
Accessories Aventa air filter kit, 2 pcs for air distributor, not for air distributor small (Part. No.
Installation dimensions (in mm) Determined on the basis of EN 14511 or Truma test conditions 265 785 25 - 110 670 556* 523 / 496* 400 (380) 560 Figure 6 400 (350) Power supply 230 V – 240 V , 50 Hz Power consumption Cooling: 4.4 A Starting current 28 A (150 ms) Cooling power 2.2 kW (T35 / T35) Air volume flow max. 400 m³/h Usage limits +16 °C to 40 °C Maximum angle during operation 8% Weight 29.
Truma warranty policy 40 67 0 4 38 00 0 3 52 0 40 40 78 0 Repairs will be carried out during normal business hours only by Service Australia, or its duly authorised service agents, and are subject to the warranty conditions and exclusions hereunder. F R O N T 35 The warranty is given by Service Australia for 12 months from the date of purchase against any defect arising from faulty materials or workmanship.