Product Manual

7
Technical data
Determined on the basis of EN 14511 or Truma test conditions.
Power supply
230 V – 240 V ~, 50 Hz
Power consumption
Cooling: 4.2 A
Heating: 3.7 A
Starting current
28 A (150 ms)
Cooling power
2.4 kW
Heating power
1.7 kW (heat pump)
Air volume flow
max. 400 m³/hr.
Usage limits
+4 °C to 40°C.
Maximum angle during operation
8%
Weight
33 kg plus installation materials
Dimensions (W x H x D)
External: 660 x 248 x 1008 mm
Internal: 523 x 46 x 670 mm
Refrigerant
R 407C
Refrigerant content
see type plate on unit
Right reserved to make technical changes!
Accessories
Filter set, 2 pieces (part no. 40091-16800).
Fig. 5
Troubleshooting
Fault Cause / Remedy
Device not cooling Thawing procedure in progress
Remote control temperature
setting reached or too high
Device not heating Defrosting process running
(outside temperature between
4°C and 7°C
Outside temperature below 4°C
Device cooling /
heating inadequately
ornot at all
Filter soiled, change filter.
External air routes soiled /
blocked
Moisture on underside
of air distributor
Close windows and doors and
select high fan level
Water dripping out of
air distributor
Condensation trap on external
unit blocked
Seal between device and roof
not intact
System at too much of an angle
Remote control
not working
Check batteries in remote con-
trol and replace if necessary
Device not reacting
to remote control
commands
Check whether there are ob-
structions between the remote
control and the IR receiver
Is the remote control tuned to
the IR receiver? / tune remote
control to IR receiver.
If these actions do not remedy the problem, please
contact Service Australia.