Product Manual
7
Technical data
Determined on the basis of EN 14511 or Truma test conditions.
Power supply
230 V – 240 V ~, 50 Hz
Power consumption
Cooling: 4.2 A
Heating: 3.7 A
Starting current
28 A (150 ms)
Cooling power
2.4 kW
Heating power
1.7 kW (heat pump)
Air volume flow
max. 400 m³/hr.
Usage limits
+4 °C to 40°C.
Maximum angle during operation
8%
Weight
33 kg plus installation materials
Dimensions (W x H x D)
External: 660 x 248 x 1008 mm
Internal: 523 x 46 x 670 mm
Refrigerant
R 407C
Refrigerant content
see type plate on unit
Right reserved to make technical changes!
Accessories
Filter set, 2 pieces (part no. 40091-16800).
Fig. 5
Troubleshooting
Fault Cause / Remedy
Device not cooling – Thawing procedure in progress
– Remote control temperature
setting reached or too high
Device not heating – Defrosting process running
(outside temperature between
4°C and 7°C
– Outside temperature below 4°C
Device cooling /
heating inadequately
ornot at all
– Filter soiled, change filter.
– External air routes soiled /
blocked
Moisture on underside
of air distributor
– Close windows and doors and
select high fan level
Water dripping out of
air distributor
– Condensation trap on external
unit blocked
– Seal between device and roof
not intact
– System at too much of an angle
Remote control
not working
– Check batteries in remote con-
trol and replace if necessary
Device not reacting
to remote control
commands
– Check whether there are ob-
structions between the remote
control and the IR receiver
– Is the remote control tuned to
the IR receiver? / tune remote
control to IR receiver.
If these actions do not remedy the problem, please
contact Service Australia.