User's Manual

ADA HEIGHT INSTALL GUIDETEC_TM_120 REV. B 02/02/2022 Page 59 of 74
MAINTENANCE, CARE & CLEANING
FIG. 1.
Pull the kickplate off the magnets.
FIG. 2.
Never brush across the coil fins.
FIG. 3.
Verify all blockages have been removed.
IMPORTANT WARRANTY
INFORMATION
THE CLEANING OF THE CONDENSER IS NOT
COVERED BY WARRANTY!
If you have any questions, please contact your local
TRUE Manufacturing Service Department. See contact
information on pages 12, or 70.
Condenser coils accumulate dirt and require
cleaning every 30 days or as needed.
A dirty condenser coil can result in non-warranteed
repairs and/or cabinet failure.
Proper cleaning involves removing dust from the
condenser by using a soft brush, vacuuming the
condenser with a shop vac, or using CO
2
, nitrogen
or pressurized air.
Do not place any filter material in front of the
condensing coil.
IF YOU CANNOT ADEQUATELY REMOVE THE
DIRT, PLEASE CONTACT YOUR LICENSED
REFRIGERATION SERVICE PROVIDER.
CONDENSATION
Excessive condensation can be caused by leaving the
door/drawer open for long periods of time or running
the cabinet with little to no product inside.